Skip Navigation



BJA Advance Access published online on April 17, 2009

British Journal of Anaesthesia, doi:10.1093/bja/aep064
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
102/6/869    most recent
aep064v1
Right arrow E-Letters: Submit a response to the article
Right arrow E-letters: View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Lee, H. J.
Right arrow Articles by Shim, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, H. J.
Right arrow Articles by Shim, J. C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author [2009]. Published by Oxford University Press on behalf of The Board of Directors of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournal.org

Comparison of the adductor pollicis, orbicularis oculi, and corrugator supercilii as indicators of adequacy of muscle relaxation for tracheal intubation

H. J. Lee, K. S. Kim*, J. S. Jeong, M. A. Cheong and J. C. Shim

Department of Anesthesiology and Pain Medicine, Hanyang University Hospital, #17 Haengdang dong, Sungdong gu, Seoul 133-792, Republic of Korea

* Corresponding author. E-mail: kimks{at}hanyang.ac.kr

Background: The purpose of this study was to verify which muscle among the adductor pollicis (AP), orbicularis oculi (OO), and corrugator supercilii (CS) is a better predictor of optimal intubating conditions after administration of rocuronium.

Methods: In this prospective trial, 201 patients were randomized into six groups to receive rocuronium at a dose of 0.6 or 1.0 mg kg–1 during propofol–remifentanil–nitrous oxide anaesthesia. The tracheal intubation was performed after maximal neuromuscular block by acceleromyography at the thumb (AP), the eyelid (OO), and the superciliary arch (CS). The onset time, intubating conditions, peak vital signs, and bispectral index were assessed.

Results: The onset time of rocuronium in the OO and CS muscle was significantly shorter than in the AP muscle (P<0.001), but excellent intubating conditions were significantly increased in the AP (87%) and the CS (77%) compared with the OO (32%) after a dose of 0.6 mg kg–1 of rocuronium (P<0.05).

Conclusions: After administration of rocuronium, twitch monitoring at the OO allows a faster intubation but is associated with an unacceptable incidence of inadequate intubating conditions. Excellent intubating conditions are observed most frequently with AP monitoring but with the longest delay before intubation is attempted. Monitoring of the CS allows intubation earlier than that of AP with fewer patients having excellent but no patients having inadequate intubating conditions.

Keywords: monitoring, neuromuscular function; muscle skeletal, relaxation; neuromuscular block, rocuronium


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


E-letters:

Read all E-letters

Masseter relaxation also predicts intubating conditions and is required for laryngoscopy
Kevin D Johnston
British Journal of Anaesthesia, 27 Jul 2009 [Full text]
Cosmetic procedures might affect accuracy of this technique
Tomas Tickunas, et al.
British Journal of Anaesthesia, 28 Sep 2009 [Full text]


Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.