BJA Advance Access published online on March 31, 2009

British Journal of Anaesthesia, doi:10.1093/bja/aep053
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
102/5/608    most recent
aep053v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Grossherr, M.
Right arrow Articles by Gehring, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Grossherr, M.
Right arrow Articles by Gehring, H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author [2009]. Published by Oxford University Press on behalf of The Board of Directors of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournal.org

Propofol concentration in exhaled air and arterial plasma in mechanically ventilated patients undergoing cardiac surgery

M. Grossherr1,*, A. Hengstenberg4, T. Meier1, L. Dibbelt2, B. W. Igl3, A. Ziegler3, P. Schmucker1 and H. Gehring1

1 Department of Anaesthesiology
2 Institute of Clinical Chemistry
3 Institute of Medical Biometry and Statistics, University of Luebeck, Ratzeburger Allee 160, D-23538 Luebeck, Germany
4 Research Unit, Draegerwerk AG & Co. KGaA, Luebeck, Germany

* Corresponding author. E-mail: martin_grossherr{at}hotmail.com

Background: Measuring propofol concentration in plasma (cPPL) and in exhaled alveolar gas (cPG) during constant infusion provides information about their respective time courses. In the present study, we compared these time courses in patients undergoing cardiac surgery from the beginning of propofol anaesthesia until eye opening upon awakening.

Methods: The cPG was measured before, during, and after continuous infusion of propofol for general anaesthesia in 12 patients at two randomly allocated doses (3 or 6 mg kg–1 h–1). Gas samples were collected on Tenax tubes. After thermodesorption, cPG was measured by gas chromatography mass spectrometry. Simultaneously with exhaled gas, arterial blood was sampled for measuring cPPL by reversed-phase high-performance liquid chromatography with fluorescence detection. In order to compare the time courses of cPPL and cPG as dimensionless values directly, each gas and plasma value was normalized by relating it to the corresponding value at the end of the initial infusion after 40 min.

Results: The cPG ranged between 2.8 and 22.5 ppb, whereas the corresponding cPPL varied between 0.3 and 3.3 µg ml–1. Normalized concentration values showed a delayed increase in cPG compared with cPPL under constant propofol infusion before the onset of cardiopulmonary bypass, and a delayed decrease after stopping the propofol at the end of anaesthesia.

Conclusions: Propofol can be measured in exhaled gas from the beginning until the end of propofol anaesthesia. The different time courses of cPPL and cPG have to be considered when interpreting cPG.

Keywords: anaesthetics i.v., propofol; measurement techniques, chromatography, mass spectrometry, drug concentration; monitoring


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
T. Perl, E. Carstens, A. Hirn, M. Quintel, W. Vautz, J. Nolte, and M. Junger
Determination of serum propofol concentrations by breath analysis using ion mobility spectrometry
Br. J. Anaesth., December 1, 2009; 103(6): 822 - 827.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.