Skip Navigation



BJA Advance Access published online on March 11, 2009

British Journal of Anaesthesia, doi:10.1093/bja/aep040
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
102/5/667    most recent
aep040v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Kawaguchi, M.
Right arrow Articles by Kazama, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kawaguchi, M.
Right arrow Articles by Kazama, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Board of Management and Trustees of the British Journal of Anaesthesia 2009. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Rocuronium dose-dependently suppresses the spectral entropy response to tracheal intubation during propofol anaesthesia

M. Kawaguchi, I. Takamatsu* and T. Kazama

Department of Anesthesiology, National Defense Medical College, 3-2 Namiki, Tokorozawa, Saitama 359-8513, Japan

* Corresponding author. E-mail: tisao{at}ndmc.ac.jp

Background: The EntropyTM Module anaesthesia monitor displays two spectral entropy-based indices, response entropy (RE) and state entropy (SE). The difference between RE and SE (RE–SE), which mainly reflects electromyography activation, is thought to indicate the adequacy of antinociception. Little is known, however, about the effects of neuromuscular blocking agents on the RE–SE. We investigated the effects of rocuronium on the RE–SE response to tracheal intubation.

Methods: Forty-four patients were randomly assigned to receive one of four rocuronium doses (0.3, 0.6, 0.9, and 1.2 mg kg–1). Anaesthesia was induced by propofol target-controlled infusion. Rocuronium was administered 2 min after anaesthesia induction. Tracheal intubation was performed 7 min after anaesthesia induction. Arterial pressure, heart rate (HR), bispectral index (BIS), RE, SE, and patient movement were recorded.

Results: All EEG-derived indices (BIS, RE, SE, and RE–SE) increased after tracheal intubation. The maximum increase in the indices after tracheal intubation was significantly suppressed by an increase in the rocuronium dose. Patient movement after tracheal intubation was suppressed by an increase in the rocuronium dose. All indices were higher in patients who moved during or after tracheal intubation than in those who did not move. Rocuronium dose did not affect the mean arterial pressure or HR in response to tracheal intubation.

Conclusions: The RE–SE response to tracheal intubation was suppressed by increasing the rocuronium dose. Estimates of nociception using RE–SE should be interpreted carefully in different states of muscle paralysis during general anaesthesia.

Keywords: anaesthetics i.v., propofol; brain, electroencephalography; monitoring, bispectral index; monitoring, electroencephalography; neuromuscular block, rocuronium


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
D. M. Mathews, A. J. Aho, A. Yli-Hankala, L.-P. Lyytikainen, and V. Jantti
Response entropy-state entropy difference and nociception: a matter of context
Br. J. Anaesth., July 1, 2009; 103(1): 135 - 137.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.