Skip Navigation



BJA Advance Access published online on February 25, 2009

British Journal of Anaesthesia, doi:10.1093/bja/aep021
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
102/4/499    most recent
aep021v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Rath, G. P.
Right arrow Articles by Dash, H. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rath, G. P.
Right arrow Articles by Dash, H. H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Board of Management and Trustees of the British Journal of Anaesthesia 2009. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Saline flush test for bedside detection of misplaced subclavian vein catheter into ipsilateral internal jugular vein{dagger}

G. P. Rath1,*, P. K. Bithal1, G. R. Toshniwal2, H. Prabhakar1 and H. H. Dash1

1 Department of Neuroanaesthesiology, Neurosciences Center, All India Institute of Medical Sciences, New Delhi, India
2 Wayne State University/Detroit Medical Center, Detroit, MI, USA

* Corresponding author. E-mail: girijarath{at}yahoo.co.in

Background: The most common misplacement during subclavian vein (SCV) catheterization is into the ipsilateral internal jugular vein (IJV). Chest radiography is the gold standard for the confirmation of correct placement. However, it is time-consuming and has the disadvantage of radiation exposure. We assessed the sensitivity and specificity of our previously reported ‘flush test’ for confirming correct central line placement.

Methods: All neurosurgical patients who underwent successful SCV catheterization on the right side by an infraclavicular approach were enrolled in this study. The flush test was performed by injecting 10 ml of normal saline in the distal port of catheter, while anterior angle of ipsilateral neck was palpated by an independent observer. A thrill of fluid elicited on the palm of hand (positive test) was suggestive of misplaced catheter into ipsilateral IJV. This was confirmed with chest fluoroscopy.

Results: SCV catheterization was performed in 570 patients. The flush test was positive in 19 patients (3.3%) and negative in 551 patients (96.7%). There were 26 (4.6%) misplacements as detected by chest radiography; 19 entered the IJV (3.3%) and seven the contralateral SCV (1.2%). In all patients who had a misplaced catheter into the ipsilateral IJV, the flush test results were positive, whereas the results were negative in patients who had normally placed catheter or misplaced catheter elsewhere. It was found that the test had 100% sensitivity and specificity to detect misplacement of SCV catheter into the ipsilateral IJV.

Conclusions: Saline flush test is a simple and sensitive bedside test that successfully detects misplaced SCV catheters into ipsilateral IJV.

Keywords: complications, catheter misplacement; equipment, central venous catheter; vein, subclavian cannulation; vein, internal jugular; technique, flush test


{dagger} Presented at 2008 SNACC and ASA Annual Meetings held at Orlando, FL, USA.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.