Skip Navigation



BJA Advance Access published online on November 19, 2008

British Journal of Anaesthesia, doi:10.1093/bja/aen327
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
102/1/61    most recent
aen327v1
Right arrow E-Letters: Submit a response to the article
Right arrow E-letters: View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Zhang, X.-J.
Right arrow Articles by Zhong, N.-S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zhang, X.-J.
Right arrow Articles by Zhong, N.-S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Board of Management and Trustees of the British Journal of Anaesthesia 2008. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Effect of propofol on twitch diaphragmatic pressure evoked by cervical magnetic stimulation in patients

X.-J. Zhang1, G. Yu1,*, X.-H. Wen1, Z.-C. Lin1, F.-Q. Yang1, Z.-G. Zheng2, R.-C. Chen2 and N.-S. Zhong2

1 Department of Anaesthesiology
2 Guangzhou Institute of Respiratory Disease, First Affiliated Hospital of Guangzhou Medical College, No. 151 Yanjiangxi Road, Guangzhou 510120, China

* Corresponding author. E-mail: yu2ge3{at}yahoo.com.cn

Background: Several studies have demonstrated the inhibitory effect of propofol on diaphragmatic contractility in laboratory animals, but there have been few studies in humans. We have investigated the effect of a single bolus injection of propofol on twitch diaphragmatic pressure (TwPdi) evoked by cervical supramaximal magnetic stimulation, and its impact on diaphragmatic contractility.

Methods: In 16 patients scheduled for elective operation, TwPdi was evoked bilaterally at the cervical phrenic nerves with supramaximal magnetic stimulations using a 140 mm diameter magnetic coil. Changes of TwPdi were monitored dynamically before and during general anaesthesia induced by single bolus of propofol 2 mg kg –1. During the study, all patients breathed 100% oxygen by a face mask, maintaining SpO2 ≥99% and PE'CO2 4.6–5.2 kPa.

Results: TwPdi declined after administration of propofol with gradual recovery. Compared with baseline [20.6 (6.0) cm H2O], TwPdi decreased by 23.3% (P<0.001) to [15.8 (6.4) cm H2O]. When the patients regained awareness, TwPdi returned to [19.1 (6.1) cm H2O], close to baseline (P=0.063). The time from starting the propofol infusion to the lowest TwPdi was [240 (86) s]. Total time course of stimulation lasted [363 (89) s].

Conclusions: A single bolus propofol depressed TwPdi evoked by cervical magnetic stimulation, demonstrating inhibitory effects of propofol on diaphragmatic contractility in patients during general anaesthesia.

Keywords: anaesthetic techniques, i.v. bolus; anaesthetics i.v., propofol; monitoring, neuromuscular function; muscle skeletal, diaphragm


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


E-letters:

Read all E-letters

Similar, preferably isometric, conditions are needed to assess diaphragm contractility.
Gordon B Drummond
British Journal of Anaesthesia, 10 Jan 2009 [Full text]
Effect of propofol on twitch diaphragmatic pressure
Ping Chen
British Journal of Anaesthesia, 10 Jan 2009 [Full text]


Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.