Skip Navigation



BJA Advance Access published online on September 9, 2008

British Journal of Anaesthesia, doi:10.1093/bja/aen231
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
101/5/723    most recent
aen231v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Malik, M. A.
Right arrow Articles by Laffey, J. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Malik, M. A.
Right arrow Articles by Laffey, J. G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Board of Management and Trustees of the British Journal of Anaesthesia 2008. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Comparison of Macintosh, Truview EVO2®, Glidescope®, and Airwayscope® laryngoscope use in patients with cervical spine immobilization

M. A. Malik1,2, C. H. Maharaj3, B. H. Harte1 and J. G. Laffey1,2,*

1 Department of Anaesthesia, Clinical Sciences Institute, Galway University Hospitals, Galway, Ireland
2 Clinical Research Facility, National University of Ireland, Galway, Ireland
3 Department of Anaesthesia, Sligo General Hospital, Sligo, Ireland

* Corresponding author. E-mail: john.laffey{at}nuigalway.ie

Background: The purpose of this study was to evaluate the effectiveness of the Pentax AWS®, Glidescope®, and the Truview EVO2®, in comparison with the Macintosh laryngoscope, when performing tracheal intubation in patients with neck immobilization using manual in-line axial cervical spine stabilization.

Methods: One hundred and twenty consenting patients presenting for surgery requiring tracheal intubation were randomly assigned to undergo intubation using a Macintosh (n=30), Glidescope® (n=30), Truview EVO2® (n=30), or AWS® (n=30) laryngoscope. All patients were intubated by one of the three anaesthetists experienced in the use of each laryngoscope.

Results: The Glidescope®, AWS®, and Truview EVO2® each reduced the intubation difficulty score (IDS), improved the Cormack and Lehane glottic view, and reduced the need for optimization manoeuvres, compared with the Macintosh. The mean IDS was significantly lower with the Glidescope® and AWS® compared with the Truview EVO2® device, and the IDS was lowest with the AWS®. The duration of tracheal intubation attempts was significantly shorter with the Macintosh compared with the other devices. There were no differences in success rates between the devices tested. The AWS® produced the least haemodynamic stimulation.

Conclusions: The Glidescope® and AWS® laryngoscopes required more time but reduced intubation difficulty and improved glottic view over the Macintosh laryngoscope more than the Truview EVO2® laryngoscope when used in patients undergoing cervical spine immobilization.

Keywords: anaesthetic techniques, laryngoscopy; complications, intubation tracheal; complications, spinal injury; equipment, laryngoscopes; larynx, laryngoscopy


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
M. A. Malik, R. Subramaniam, C. H. Maharaj, B. H. Harte, and J. G. Laffey
Randomized controlled trial of the Pentax AWS(R), Glidescope(R), and Macintosh laryngoscopes in predicted difficult intubation
Br. J. Anaesth., November 1, 2009; 103(5): 761 - 768.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
E. H. C. Liu, R. W. L. Goy, B. H. Tan, and T. Asai
Tracheal intubation with videolaryngoscopes in patients with cervical spine immobilization: a randomized trial of the Airway Scope(R) and the GlideScope(R)
Br. J. Anaesth., September 1, 2009; 103(3): 446 - 451.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
F. Martin and D. J. Buggy
New airway equipment: opportunities for enhanced safety
Br. J. Anaesth., June 1, 2009; 102(6): 734 - 738.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
M. A. Malik, R. Subramaniam, S. Churasia, C. H. Maharaj, B. H. Harte, and J. G. Laffey
Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope(R), LMA CTrach(R), and the Macintosh laryngoscopes
Br. J. Anaesth., May 1, 2009; 102(5): 654 - 661.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.