Skip Navigation



BJA Advance Access published online on April 25, 2007

British Journal of Anaesthesia, doi:10.1093/bja/aem094
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
98/6/835    most recent
aem094v1
Right arrow E-Letters: Submit a response to the article
Right arrow E-letters: View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Anwer, H. M. F.
Right arrow Articles by Shehata, E. A. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Anwer, H. M. F.
Right arrow Articles by Shehata, E. A. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Board of Management and Trustees of the British Journal of Anaesthesia 2007. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Submandibular approach for tracheal intubation in patients with panfacial fractures

H. M. F. Anwer1,*, I. M. Zeitoun2 and E. A. A. Shehata2

1 Department of Anaesthesia
2 Department of Maxillofacial Surgery, Faculty of Medicine, Alexandria University, Egypt

* Corresponding author: Department of Anaesthesia, Faculty of Medicine, Alexandria University, 51 Kafr Abdo St Zahran Towers, Rushdy, Alexandria, Egypt. E-mail: hfanwer{at}yahoo.com

Background: The oral route for tracheal intubation can interfere with some maxillofacial surgical procedures. At the same time, the nasal route can be contraindicated or impossible. Tracheostomy is the usual solution in these circumstances, but it carries a high incidence of complications. We tested the submandibular route for tracheal intubation as an alternative to tracheostomy in such situations.

Methods: The procedure was performed in 13 patients suffering from panfacial fractures associated with a fracture of skull base or a displaced nasal fracture, and in one patient with post-caustic burn scar affecting most of the face including the nose and requiring a full thickness skin flap surrounding the mouth.

Results: The technique was found easy and satisfactory for both the surgeon and the anaesthetist. It allowed uninterrupted surgical techniques and a secure airway. In six of the 13 patients, the submandibular tracheal tube was left in place for up to 44 h in the intensive care unit after the operation without complications or difficulties. Accidental dislodgement of the tube to the right main bronchus occurred in two patients while carrying out the procedure; it was rapidly detected and corrected. In another two patients, postoperative superficial infection occurred that responded well to local treatment. No other complications were encountered.

Conclusions: Submandibular tracheal intubation is a simple and effective technique for upper airway management in some maxillofacial surgical patients when both oral and nasal tracheal intubations are not convenient.

Keywords: airway; complications, intubation tracheal; surgery, maxillofacial


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


E-letters:

Read all E-letters

Submandibular approach for tracheal intubation in patients with panfacial fractures
Muhammad Farooq
British Journal of Anaesthesia, 1 Jun 2007 [Full text]
Submandibular approach for tracheal intubation in patients with panfacial fractures.
Wilson Thomas
British Journal of Anaesthesia, 10 Jun 2007 [Full text]
MAGILL OR MCGILL
DR. SHASHI KIRAN, et al.
British Journal of Anaesthesia, 18 Feb 2008 [Full text]


Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.