Skip Navigation



BJA Advance Access published online on March 19, 2007

British Journal of Anaesthesia, doi:10.1093/bja/aem049
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
98/5/581    most recent
aem049v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Annecke, T.
Right arrow Articles by Conzen, P. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Annecke, T.
Right arrow Articles by Conzen, P. F.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Board of Management and Trustees of the British Journal of Anaesthesia 2007. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Effects of sevoflurane and propofol on ischaemia–reperfusion injury after thoracic-aortic occlusion in pigs

T. Annecke1,2, J. C. Kubitz1,2, S. Kahr2, J. M. Hilberath2, K. Langer2, G. I. Kemming1,2, M. Rehm1, I. Bittmann3 and P. F. Conzen1,*

1 Clinic of Anaesthesiology
2 Institute for Surgical Research
3 Institute for Pathology, Ludwig-Maximilians-University, Munich, Germany

* Corresponding author: Clinic of Anaesthesiology, University Hospital, Nussbaumstr. 20, D-80336 Munich, Germany. E-mail: peter.conzen{at}med.uni-muenchen.de

Background: Thoraco-abdominal-aneurysm surgery predicts high mortality. Propofol and sevoflurane are commonly used anaesthetics for this procedure. Halogenated anaesthetics induce organ protection similar to ischaemic preconditioning. We investigated which anaesthetic regimen would lead to a better protection against ischaemia–reperfusion injury induced by temporary thoracic-aortic occlusion.

Methods: Following initial fentanyl–midazolam anaesthesia for surgical preparation, 18 pigs were randomly assigned to two groups: group one received propofol (n=9) and group two sevoflurane (n=9) before, during, and after lower body ischaemia in an investigator blinded fashion. Ten animals without aortic occlusion served as time controls (propofol, n=5; sevoflurane, n=5). For induction of ischaemia, the thoracic aorta was occluded by a balloon-catheter for 90 min. After 120 min of reperfusion, the study anaesthetics were discontinued and fentanyl–midazolam re-established for an additional 180 min. Goal-directed therapy was performed during reperfusion. Fluid and catecholamine requirements were assessed. Serum samples and intestinal tissue specimens were obtained.

Results: Severe declamping shock occurred in both study groups. While norepinephrine requirements in the sevoflurane group were significantly reduced during reperfusion (P < 0.05), allowing cessation of catecholamine support in 4/9 animals, all 9/9 animals were still catecholamine dependent at the end of the experiment in the propofol group. Serum activities of lactate dehydrogenase, aspartate transaminase, and alanine aminotransferase were lower with sevoflurane (P < 0.05). Small intestine tissue specimens did not differ histologically.

Conclusions: Use of sevoflurane compared with propofol attenuated the haemodynamic sequelae of reperfusion injury in our model. Release of serum markers of cellular injury was also attenuated.

Keywords: anaesthetics i.v., propofol; anaesthetics volatile, sevoflurane; arteries, aortic clamp; surgery, vascular


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.