Skip Navigation



BJA Advance Access published online on March 10, 2006

British Journal of Anaesthesia, doi:10.1093/bja/ael050
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
96/5/620    most recent
ael050v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Takamatsu, I.
Right arrow Articles by Kazama, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Takamatsu, I.
Right arrow Articles by Kazama, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Board of Management and Trustees of the British Journal of Anaesthesia 2006. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org
Accepted January 17, 2006

Clinical Investigation

Entropy indices vs the bispectral indexTM for estimating nociception during sevoflurane anaesthesia

I. Takamatsu 1 *, M. Ozaki 2, and T. Kazama 1

1 Department of Anaesthesiology, National Defense Medical College, Tokorozawa, Saitama, Japan
2 Department of Anaesthesiology, Tokyo Women's Medical University, Tokyo, Japan

* To whom correspondence should be addressed.
I. Takamatsu, E-mail: tisao{at}dia-net.ne.jp


   Abstract

Background. It is now possible to acquire and process raw EEG and frontal EMG signals to produce two spectral-entropy-based indices (response entropy and state entropy) reflective of analgesic and hypnotic levels during general anaesthesia (with the Datex-Ohmeda S/5 Entropy Module, Datex-Ohmeda, Helsinki, Finland). However, there are no data available on the accuracy of the Entropy Module in estimating nociception during sevoflurane anaesthesia.

Methods. Forty female patients were enrolled in the present study. Each patient was allocated randomly to one of four end-tidal sevoflurane concentration (ETsev) groups (1.3, 1.7, 2.1 or 2.5%). A BIS SensorTM (Aspect Medical Systems, Newton, MA) and an Entropy SensorTM (Datex-Ohmeda) were applied side-by-side to the forehead. The bispectral index (A-2000 BIS Monitor, version 3.4, Aspect Medical Systems), response entropy, state entropy and patient movement were observed after electrical stimulation (20, 40, 60 and 80 mA, 100 Hz, 5 s) and after skin incision during sevoflurane anaesthesia (1.3, 1.7, 2.1 or 2.5%). Accuracy of the EEG variables in differentiating the intensity of electrical stimulation was estimated by the prediction probability (PK) values.

Results. Response entropy and state entropy [median, (range)] before skin incision were significantly lower in patients who did not move [29 (15-41) and 24 (14-41)] than in those that did [38 (24-53) and 37 (24-52)], but there was no significant difference in BIS. All EEG variables increased significantly (P<0.0001 for all) with increases in the intensity of electrical stimulation. The difference between response entropy and state entropy increased with increases in the electrical stimulation (P<0.0001). However, no EEG variables could differentiate the intensity of the electrical stimulations accurately because of low PK-values (PK<0.8).

Conclusion. Noxious stimulation increased the difference between response entropy and state entropy. However, an increase in the difference does not always indicate inadequate analgesia and should be interpreted carefully during anaesthesia.

Keywords: anaesthetics volatile, sevoflurane; measurement techniques, spectral analysis; monitoring, bispectral index; potency, analgesic.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
M. Kawaguchi, I. Takamatsu, and T. Kazama
Rocuronium dose-dependently suppresses the spectral entropy response to tracheal intubation during propofol anaesthesia
Br. J. Anaesth., May 1, 2009; 102(5): 667 - 672.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
M. Kawaguchi, I. Takamatsu, K. Masui, and T. Kazama
Effect of landiolol on bispectral index and spectral entropy responses to tracheal intubation during propofol anaesthesia
Br. J. Anaesth., August 1, 2008; 101(2): 273 - 278.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
T. Nishiyama
The Effects of Auditory Evoked Potential Click Sounds on Bispectral Index and Entropy
Anesth. Analg., August 1, 2008; 107(2): 545 - 548.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
C. N. Sessler and K. Varney
Patient-Focused Sedation and Analgesia in the ICU*
Chest, February 1, 2008; 133(2): 552 - 565.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
G. Weil, S. Passot, F. Servin, and V. Billard
Does Spectral Entropy Reflect the Response to Intubation or Incision During Propofol-Remifentanil Anesthesia?
Anesth. Analg., January 1, 2008; 106(1): 152 - 159.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
C. Jeleazcov, J. Schmidt, B. Schmitz, K. Becke, and S. Albrecht
EEG variables as measures of arousal during propofol anaesthesia for general surgery in children: rational selection and age dependence
Br. J. Anaesth., December 1, 2007; 99(6): 845 - 854.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
D. M. Mathews, P. M. Cirullo, M. M. R. F. Struys, T. De Smet, R. J. Malik, C. L. Chang, and G. G. Neuman
Feasibility study for the administration of remifentanil based on the difference between response entropy and state entropy
Br. J. Anaesth., June 1, 2007; 98(6): 785 - 791.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.