Skip Navigation



BJA Advance Access published online on July 15, 2005

British Journal of Anaesthesia, doi:10.1093/bja/aei194
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
95/3/410    most recent
aei194v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Silva-Costa-Gomes, T.
Right arrow Articles by Puig, M. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Silva-Costa-Gomes, T.
Right arrow Articles by Puig, M. M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Board of Management and Trustees of the British Journal of Anaesthesia 2005. All rights reserved. For Permissions, please e-mail: journal.permissions@oupjournals.org
Accepted May 16, 2005

Clinical Investigation

Low- vs high-dose almitrine combined with nitric oxide to prevent hypoxia during open-chest one-lung ventilation

T. Silva-Costa-Gomes 1, L. Gallart 1*, J. Vallès 1, L. Trillo 1, J. Minguella 2, and M. M. Puig 1

1 Department of Anesthesiology, Hospital Universitari del Mar, Institut Municipal d'Investigacions Mèdiques (IMIM), Universitat Autònoma de Barcelona, Barcelona, Spain
2 Department of Surgery, Hospital Universitari del Mar, Institut Municipal d'Investigacions Mèdiques (IMIM), Universitat Autònoma de Barcelona, Barcelona, Spain

* To whom correspondence should be addressed.
L. Gallart, E-mail: LGallart{at}imas.imim.es


   Abstract

Background. Almitrine combined with inhaled nitric oxide (NO) can prevent hypoxia during one-lung ventilation (OLV). The optimal dose of almitrine that would provide therapeutic advantage with few side-effects during open-chest OLV has not been established.

Methods. Forty-two patients undergoing thoracotomy were randomly allocated to three groups: placebo, almitrine 4 µg kg-1 min-1 and inhaled NO 10 p.p.m. (ALM4+NO), and almitrine 16 µg kg-1 min-1 and inhaled NO 10 p.p.m. (ALM16+NO). Gas exchange, haemodynamic and respiratory variables and plasma concentrations of almitrine and lactate were monitored. Measurements were obtained with the patient awake (baseline), after induction of anaesthesia with two-lung ventilation (control 2LV), 20 min after treatment (2LV+T), and then at 10, 20 and 30 min of OLV (OLV10', OLV20' and OLV30') with FIO21.

Results. In the placebo group, OLV impaired PaO2 and increased pulmonary shunt [16 (SD 7) kPa and 42 (10)% respectively]. These improved with ALM4+NO [26 (10) kPa and 31 (7)%; P<0.001]. ALM16+NO further improved PaO2 to 36 (13) kPa (P<0.0001) but gave no improvement in the shunt. Mean pulmonary artery pressure was similar in the placebo and ALM4+NO groups [20 (4) vs 23 (5) mm Hg], whereas it was increased in the ALM16+NO group to 28 (8) mm Hg (P<0.01). Plasma concentrations of almitrine and lactate were unaltered by the treatments.

Conclusions. Low-dose almitrine (4 µg kg-1 min-1) together with inhaled NO significantly improves oxygenation during open-chest OLV, without modifying pulmonary haemodynamics. An increased dose of almitrine (16 µg kg-1 min-1) with inhaled NO further improves arterial oxygenation, but also increases mean pulmonary artery pressure.

Keywords: almitrine; complications, hypoxia; nitric oxide; surgery, thoracic.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.