Skip Navigation



BJA Advance Access published online on May 20, 2005

British Journal of Anaesthesia, doi:10.1093/bja/aei153
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
95/2/166    most recent
aei153v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Baumert, J.-H.
Right arrow Articles by Rossaint, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baumert, J.-H.
Right arrow Articles by Rossaint, R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Board of Management and Trustees of the British Journal of Anaesthesia 2005. All rights reserved. For Permissions, please e-mail: journal.permissions@oupjournals.org
Accepted March 24, 2005

Laboratory Investigation

Effects of xenon anaesthesia on the circulatory response to hypoventilation

J.-H. Baumert 1*, K. E. Hecker 1, M. Hein 1, M. Reyle-Hahn 2, N. A. Horn 1, and R. Rossaint 1

1 Anaesthesiology Clinic, Universitaetsklinikum Aachen, Germany
2 Anaesthesia Department, Waldkrankenhaus Berlin-Spandau, Germany

* To whom correspondence should be addressed.
J.-H. Baumert, E-mail: jbaumert{at}ukaachen.de


   Abstract

Background. Circulatory response to hypoventilation is aimed at eliminating carbon dioxide and maintaining oxygen delivery (DO2) by increasing cardiac output (CO). The hypothesis that this increase is more pronounced with xenon than with isoflurane anaesthesia was tested in pigs.

Methods. Twenty pigs received anaesthesia with xenon 0.55 MAC/remifentanil 0.5 µg kg-1 min-1 (group X, n=10) or isoflurane 0.55 MAC/remifentanil 0.5 µg kg-1min-1 (group I, n=10). CO, heart rate (HR), mean arterial pressure (MAP) and left ventricular fractional area change (FAC) were measured at baseline, after 5 and 15 min of hypoventilation and after 5, 15 and 30 min of restored ventilation.

Results. CO increased by 10-20% with both anaesthetics, with an equivalent rise in HR, maintaining DO2 in spite of a 20% reduction in arterial oxygen content. Decreased left ventricular (LV) afterload during hypoventilation increased FAC, and this was more marked with xenon (0.60-0.66, P<0.05 compared with baseline and isoflurane). This difference is attributed to negative inotropic effects of isoflurane. Increased pulmonary vascular resistance during hypoventilation was found with both anaesthetics.

Conclusion. The cardiovascular effects observed in this model of moderate hypoventilation were sufficient to maintain DO2. Although the haemodynamic response appeared more pronounced with xenon, differences were not clinically relevant. An increase in FAC with xenon is attributed to its lack of negative inotropic effects.

Keywords: anaesthetics gases, xenon; complications, hypercarbia; complications, hypoxaemia; monitoring, trans-oesophageal echocardiography.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.