BJA Advance Access published online on February 18, 2005
British Journal of Anaesthesia, doi:10.1093/bja/aei092
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1 Department of Anaesthesia, Akita University School of Medicine, Akita City 010-8543, Japan
* To whom correspondence should be addressed. Background. This study was designed to determine cardiovagal baroreflex gain during propofol infusion and to characterize its recovery profile using the pharmacological and spontaneous sequence methods in 13 healthy volunteers without cardiovascular or autonomic disorders. Methods. After an 8- to 10-h fast and no premedication, measurements of RR intervals obtained from the electrocardiogram and non-invasive beat-to-beat systolic blood pressure (SP) were made at conscious baseline, at 60 and 120 min after induction of general anaesthesia using propofol, and at 20, 60, 120 and 180 min after emergence from anaesthesia. During propofol anaesthesia, ventilation was mechanically controlled to maintain normocapnia and calculated propofol concentration was adjusted by a TCI system at 5 µg ml-1. Baroreflex responses were triggered by bolus i.v. injections of phenylephrine and nitroprusside to alter SP by 15-30 mm Hg. The linear portions of the baroreflex curves relating RR intervals and SP by least-square regression analysis were determined to obtain pharmacological gains. In addition, spontaneous sequence baroreflex gains were calculated from spontaneously fluctuating SP and RR intervals. Results. Baseline pressor and depressor test gains before propofol anaesthesia were 29.1 (SD 14.9) and 12.5 (7.8) ms mm Hg-1, respectively. They were significantly depressed by 65-73% during propofol infusions. Similarly, baseline up- and down-sequence baroreflex gains were 33.8 (28.9) and 27.3 (19.8) ms mm Hg-1, respectively, and were significantly depressed by 71-87% during propofol anaesthesia. Pressor test and up-sequence baroreflex gains returned to the baseline values 20 min after emergence from propofol anaesthesia, but depressor test and down-sequence baroreflex gains did not recover until 60 min after emergence. Conclusions. We conclude that heart rate responses to both lowering and elevating blood pressure were depressed by propofol anaesthesia, and 60 min was required for their full recovery after discontinuation of propofol infusion.
Accepted September 24, 2004
Clinical Investigation
Baroreflex control of heart rate during and after propofol infusion in humans
M. Tanaka, E-mail: mtanaka{at}med.akita-u.ac.jp
![]()
Abstract ![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
M. Zaballos, C. Jimeno, J. Almendral, F. Atienza, D. Patino, E. Valdes, J. Navia, and M. J. Anadon Cardiac electrophysiological effects of remifentanil: study in a closed-chest porcine model Br. J. Anaesth., August 1, 2009; 103(2): 191 - 198. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Nassar and A. A. Abdel-Rahman Brainstem Adenosine A1 Receptor Signaling Masks Phosphorylated Extracellular Signal-Regulated Kinase 1/2-Dependent Hypotensive Action of Clonidine in Conscious Normotensive Rats J. Pharmacol. Exp. Ther., January 1, 2009; 328(1): 83 - 89. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. S. Xue, Y. C. Xu, Y. Liu, Q. Y. Yang, X. Liao, H. P. Liu, Y. M. Zhang, J. H. Liu, and M. P. Luo Different small-dose sufentanil blunting cardiovascular responses to laryngoscopy and intubation in children: a randomized, double-blind comparison Br. J. Anaesth., May 1, 2008; 100(5): 717 - 723. [Abstract] [Full Text] [PDF] |
||||

