Skip Navigation



BJA Advance Access published online on January 14, 2005

British Journal of Anaesthesia, doi:10.1093/bja/aei054
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
94/3/287    most recent
aei054v1
Right arrow E-Letters: Submit a response to the article
Right arrow E-letters: View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Tan, H. L.
Right arrow Articles by van Heerden, P. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tan, H. L.
Right arrow Articles by van Heerden, P. V.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Board of Management and Trustees of the British Journal of Anaesthesia 2005
Accepted November 11, 2004

Clinical Investigation

Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit

H. L. Tan 1, M. Pinder 1, R. Parsons 1, B. Roberts 1, and P. V. van Heerden 1*

1 Department of Intensive Care, Sir Charles Gairdner Hospital and Pharmacology Unit, School of Medicine and Pharmacology, University of Western Australia, Perth, Australia

* To whom correspondence should be addressed.
P. V. van Heerden, E-mail: peter.vanheerden{at}health.wa.gov.au


   Abstract

Background. The USCOM ultrasonic cardiac output monitor (USCOM Pty Ltd, Coffs Harbour, NSW, Australia) is a non-invasive device that determines cardiac output by continuous-wave Doppler ultrasound. The aim of this study was to evaluate the accuracy of the USCOM device compared with the thermodilution technique in intensive care patients who had just undergone cardiac surgery.

Methods. We conducted a prospective study in the 18-bed intensive care unit of a 600-bed tertiary referral hospital. Twenty-four mechanically ventilated patients were studied immediately following cardiac surgery. We evaluated the USCOM monitor by comparing its output with paired measurements obtained by the standard thermodilution technique using a pulmonary artery catheter.

Results. Forty paired measurements were obtained in 22 patients. We were unable to obtain an acceptable signal in the remaining two patients. Comparison of the two techniques showed a bias of 0.18 and limits of agreement of -1.43 to 1.78. The agreement may not be as good between techniques at higher cardiac output values.

Conclusions. The USCOM monitor has a place in intensive care monitoring. It is accurate, rapid, safe, well-tolerated, non-invasive and cost-effective. The learning curve for skill acquisition is very short. However, during the learning phase the USCOM monitor measurements are rather ‘operator dependent’. Its suitability for use in high and low cardiac output states requires further validation.

Keywords: measurement techniques, cardiac output; measurement techniques, non-invasive, continuous-wave Doppler ultrasound.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
W. H. L. Teoh and A. T. H. Sia
Colloid Preload Versus Coload for Spinal Anesthesia for Cesarean Delivery: The Effects on Maternal Cardiac Output
Anesth. Analg., May 1, 2009; 108(5): 1592 - 1598.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
R. Phillips, P. Lichtenthal, J. Sloniger, D. Burstow, M. West, and J. Copeland
Noninvasive Cardiac Output Measurement in Heart Failure Subjects on Circulatory Support
Anesth. Analg., March 1, 2009; 108(3): 881 - 886.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
D. J. Funk, E. W. Moretti, and T. J. Gan
Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting
Anesth. Analg., March 1, 2009; 108(3): 887 - 897.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
L. Siu, A. Tucker, S. K. Manikappa, and J. Monagle
Does Patient Position Influence Doppler Signal Quality from the USCOM Ultrasonic Cardiac Output Monitor?
Anesth. Analg., June 1, 2008; 106(6): 1798 - 1802.
[Abstract] [Full Text] [PDF]

E-letters:

Read all E-letters

Acceptable limits of agreement need to be defined a priori
Anna Lee, et al.
British Journal of Anaesthesia, 22 Mar 2005 [Full text]


Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.