Skip Navigation

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow E-letters: View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (15)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Galloway, S.
Right arrow Articles by Bodenham, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Galloway, S.
Right arrow Articles by Bodenham, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 2003, Vol. 90, No. 5 589-595
© 2003 The Board of Management and Trustees of the British Journal of Anaesthesia


Clinical Investigations

Ultrasound imaging of the axillary vein—anatomical basis for central venous access

S. Galloway and A. Bodenham

Department of Anaesthesia, Leeds General Infirmary, Great George Street, Leeds LS1 3EX, UK

Corresponding author. E-mail: andy.bodenham@leedsth.nhs.uk

Background. The central veins that are usually cannulated are the jugular, subclavian, femoral and brachial. If subclavian catheterization is difficult using surface landmark techniques, we now use ultrasound to catheterize the infraclavicular axillary vein. This approach is not widely used and the ultrasound appearance has not been formally described. We examined the anatomical relationships of the axillary vessels to guide safe cannulation of the axillary vein.

Method. In 50 subjects, we used ultrasound to examine the infraclavicular regions from below the mid-clavicular point and at 2 cm and 4 cm further laterally (described as the middle and lateral points) with the arms at 0°, 45° and at 90° abduction. We took measurements at each point, with the artery and vein seen in cross-section. The depth from the skin, vessel diameters and the distance between the vessels was measured. The amount of overlap was scaled from 0 (no overlap) to 3 (complete overlap). We also recorded (if visible) the distance between the rib cage and axillary vein. A longitudinal image of the vein was also obtained. Angle of ascent (in relation to the skin), length and depth of the vein was measured.

Results. Axillary vessels were seen in 93% of images. The mean depth from skin to vein increased from 1.9 cm (range 0.7–3.7 cm) medially to 3.1 cm (1.1–5.6 cm) laterally. The venous diameter decreased from 1.2 cm (0.3–2.1 cm) medially to 0.9 cm (0.4–1.6 cm) laterally. The arterio–venous distance increased from 0.3 cm to 0.8 cm. Median arterio–venous overlap decreased from 2/3 (mode 3/3) to 0 (0). The distance from rib cage to vein increased from 1.0 cm to 2.0 cm.

Conclusion. The axillary vein is an alternative for central venous cannulation and we present an anatomical rationale for its safe use. Less arterio–venous overlap and a greater distance between artery and vein and from vein to rib cage should provide an increased margin of safety for central venous cannulation.

Br J Anaesth 2003; 90: 589–95


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
J. C. de Graaff, L. J. Bras, and J. A. Vos
Early transection of a central venous catheter in a sedated ICU patient
Br. J. Anaesth., December 1, 2006; 97(6): 832 - 834.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
A. R. Sauter, H.-J. Smith, A. Stubhaug, M. S. Dodgson, and O. Klaastad
Use of Magnetic Resonance Imaging to Define the Anatomical Location Closest to All Three Cords of the Infraclavicular Brachial Plexus
Anesth. Analg., December 1, 2006; 103(6): 1574 - 1576.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
M. M. Gabal and A. Bodenham
Imaging of the axillary vein.
Br. J. Anaesth., September 1, 2006; 97(3): 426 - 426.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
S. P. Mackey, S. Sinha, J. Pusey, A. R. Bodenham, and S. Galloway
Ultrasound imaging of the axillary vein--anatomical basis for central venous access
Br. J. Anaesth., October 1, 2004; 93(4): 598 - 599.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
A. Sharma, A. R. Bodenham, and A. Mallick
Ultrasound-guided infraclavicular axillary vein cannulation for central venous access
Br. J. Anaesth., August 1, 2004; 93(2): 188 - 192.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
N. S. Sandhu
Transpectoral Ultrasound-Guided Catheterization of the Axillary Vein: An Alternative to Standard Catheterization of the Subclavian Vein
Anesth. Analg., July 1, 2004; 99(1): 183 - 187.
[Abstract] [Full Text] [PDF]

E-letters:

Read all E-letters

Rib cage or lung pleura interface
Mahamoud M Gabal
British Journal of Anaesthesia, 18 May 2006 [Full text]
Re: Rib cage or lung pleura interface
Andrew Bodenham
British Journal of Anaesthesia, 26 May 2006 [Full text]


Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.