Skip Navigation

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (20)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Twigg, S. J.
Right arrow Articles by Cook, T. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Twigg, S. J.
Right arrow Articles by Cook, T. M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 2003, Vol. 90, No. 1 8-13
© 2003 The Board of Management and Trustees of the British Journal of Anaesthesia


Clinical Investigations

Randomized evaluation of the performance of single-use laryngoscopes in simulated easy and difficult intubation

S. J. Twigg*, B. McCormick and T. M. Cook

Royal United Hospital, Combe Park, Bath BA1 3NG, UK*Corresponding author. E-mail: steve.twigg@lineone.net

{dagger} Presented at 35th Annual Scientific Meeting of Group of Anaesthetists in Training (GAT), June 2002, as part of the registrar’s prize competition.
{ddagger} This article is accompanied by Editorial I.

Background. Single-use laryngoscopes are becoming used more widely.

Methods. We compared six types of single-use laryngoscope with the standard Macintosh laryngoscope using the Laerdal SimManTM patient simulator. Twenty anaesthetists attempted to intubate the simulator with standardized airway settings allowing a full view of the vocal cords (‘easy intubation’). The airway settings were then changed so that only the posterior part of the glottis was visible (‘difficult intubation’) and the anaesthetists were asked to intubate the simulator again.

Results. The time to intubate with the standard laryngoscope was less in both easy (P<0.05) and difficult (P<0.01) intubations. The performance of five laryngoscopes during easy intubation (P<0.01) and four during difficult intubation (P<0.001) was significantly worse than that of the Macintosh. There was a significant difference in Cormack and Lehane grading between the laryngoscopes tested in both easy (P<0.05) and difficult (P<0.05) intubation. The percentage of glottic opening visible (POGO score) also differed between laryngoscopes in both the easy (P<0.01) and difficult (P<0.001) groups. The highest POGO scores were obtained with the Macintosh laryngoscope. During the difficult intubation simulation, the reusable Macintosh laryngoscope needed less use of a bougie and had fewer failed intubations than the single-use laryngoscopes, but these differences did not reach statistical significance.

Conclusions. Of the laryngoscopes tested, the standard reusable Macintosh laryngoscope performed best. The EuropaTM was the best single-use laryngoscope. Some single-use laryngoscopes tested were significantly inferior to the Macintosh. This raises concern over their use in clinical practice, particularly if intubation is difficult.

Br J Anaesth 2003; 90: 8–13


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
M. B. Clarke, P. Forster, and T. M. Cook
Airway management for tonsillectomy: a national survey of UK practice
Br. J. Anaesth., September 1, 2007; 99(3): 425 - 428.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
T. M. Cook
Editorial I: The classic laryngeal mask airway: a tried and tested airway. What now?
Br. J. Anaesth., February 1, 2006; 96(2): 149 - 152.
[Full Text] [PDF]


Home page
Int J Qual Health CareHome page
K. Anderson, S. Gambhir, R. Glavin, and J. Kinsella
The use of an anaesthetic simulator to assess single-use laryngoscopy equipment
Int. J. Qual. Health Care, February 1, 2006; 18(1): 17 - 22.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
M. C. Blunt and K. R. Burchett
Editorial I: Variant Creutzfeldt-Jakob disease and disposable anaesthetic equipment--balancing the risks
Br. J. Anaesth., January 1, 2003; 90(1): 1 - 3.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.