Skip Navigation

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (8)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Ishikawa, S.
Right arrow Articles by Makita, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ishikawa, S.
Right arrow Articles by Makita, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 2003, Vol. 90, No. 1 21-26
© 2003 The Board of Management and Trustees of the British Journal of Anaesthesia


Clinical Investigations

Progressive changes in arterial oxygenation during one-lung anaesthesia are related to the response to compression of the non-dependent lung

S. Ishikawa*, K. Nakazawa and K. Makita

Department of Anesthesiology and Critical Care Medicine, Tokyo Medical and Dental University, School of Medicine, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8519, Japan E-mail: ishikawa.mane@tmd.ac.jp

Background. Arterial oxygenation can change during one-lung ventilation for reasons that are not fully understood.

Methods. We studied patients during anaesthesia and one-lung ventilation, with an inspiratory oxygen fraction of 0.8. Arterial blood gas values were recorded every 10 s with a continuous intra-arterial sensor. The non-dependent lung was compressed several times during the surgical procedure, using a retractor. The change in PaO2 during and after compression of the non-dependent lung was measured.

Results. PaO2 increased significantly when the non-dependent lung was compressed, and decreased when the compression was released. The first compression of the non-dependent lung transiently increased PaO2, but the effect of the second compression on oxygenation was more marked and persistent. PaO2 increased by more than 13 kPa at 10 min after the second compression in four patients (responder group). Arterial oxygenation improved markedly in patients in this group during the surgical procedure.

Conclusion. Oxygenation can improve during one-lung ventilation in some patients. This improvement is partly related to a marked increase in PaO2 during compression of the non-dependent lung.

Br J Anaesth 2003; 90: 21–6


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
O. Pruszkowski, N. Dalibon, M. Moutafis, E. Jugan, J. D. Law-Koune, P. A. Laloe, and M. Fischler
Effects of propofol vs sevoflurane on arterial oxygenation during one-lung ventilation
Br. J. Anaesth., April 1, 2007; 98(4): 539 - 544.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
J. Pfitzer, S. Ishikawa, K. Nakazawa, and K. Makita
Acute lung injury following one-lung anaesthesia
Br. J. Anaesth., July 1, 2003; 91(1): 153 - 154.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.