Skip Navigation

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (3)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Burns, S. M.
Right arrow Articles by Wilkes, R. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burns, S. M.
Right arrow Articles by Wilkes, R. G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 2001, Vol. 86, No. 4 565-567
© 2001 The Board of Management and Trustees of the British Journal of Anaesthesia

Intrapartum epidural catheter migration: a comparative study of three dressing applications

S. M. Burns1, C. M. Cowan*,2, P. M. Barclay2 and R. G. Wilkes2

1Department of Anaesthesia, Royal Liverpool Children’s Hospital, Eaton Road, Liverpool L12 2AP, UK. 2Department of Anaesthesia, Liverpool Women’s Hospital, Crown Street, Liverpool L8 7SS, UK*Corresponding author

We compared three types of catheter fixation application for their ability to minimize the incidence and magnitude of epidural catheter movement during labour. Patients were randomized to have their epidural catheter secured by a Tegaderm dressing (group T; n=35), a Tegaderm dressing plus filter-shoulder fixation (group F; n=39), or a Niko Epi-Fix dressing (group N; n=37). The length of catheter visible at the patient’s skin surface was recorded (to the nearest 0.5 cm) after insertion and before removal; the difference was defined as ‘catheter movement’. Outward movement of the catheter was greatest when a Niko Epi-Fix was used (P<0.01). Concerning minimization of displacement of the epidural catheter per se, only a Tegaderm dressing with additional filter-shoulder fixation proved more effective than using a Niko Epi-Fix dressing (P<0.05).

Br J Anaesth 2001; 86: 565–7


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.