Skip Navigation

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (11)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Beydon, L.
Right arrow Articles by Cazalaa, J. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beydon, L.
Right arrow Articles by Cazalaa, J. B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 2001, Vol. 86, No. 3 382-387
© 2001 The Board of Management and Trustees of the British Journal of Anaesthesia

Analysis of the French health ministry’s national register of incidents involving medical devices in anaesthesia and intensive care

L. Beydon1, F. Conreux1, R. Le Gall1, D. Safran2, J. B. Cazalaa3 and the members of the ‘Sous-commission de Materiovigilance’ for Anaesthesia and Intensive Care,{dagger}

1Département d’Anaesthésie, CHU d’Angers, F-49033 Angers Cedex 01, France. 2Département d’Anaesthésie, Hôpital Necker, F-75015 Paris et Commission Nationale de Matériovigilance, France 3Département d’Anaesthésie, Hôpital Laennec, Rue de Sèvres, F-75007 Paris, France*Corresponding author

{dagger}J. Ancellin, B. Bacchi, J. M. Bedicam, V. Billard, M. A. Dauphin, S. Fougère, G. Freys, F. Fries, C. Itty, G. Krim, J. Labrousse, G. Laguenie, R. Leroyer, P. Lever, M. A. Lochet, M. P. Macquet, D. Meunier, S. Molliex, J. F. Muir, Y. Nivoche, J. C. Otteni, E. Salgues, F. Saulnier, D. Thiveaud and J. P. Viale

This study details all incidents involving medical devices used in anaesthesia and intensive care reported to the relevant authorities in France in 1998. There were 1004 reports during that year. Incidents were classified as serious (harmful to patients) in 11% of cases; death resulted in 2% of cases. Equipment for ventilation and infusion, and monitors of all kinds, accounted for most of the reports, representing 37%, 30% and 12%, respectively, of all reports. The leading causes of failure varied according to the category of device. User errors, quality control problems during production of the device and design faults were the three main causes. The problems identified during the study period enabled the faulty medical devices to be improved in 12–44% of cases. We conclude that post-marketing vigilance is a useful way of improving the quality of medical devices.

Br J Anaesth 2001; 86: 382–7


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
A. F. Smith and R. P. Mahajan
National critical incident reporting: improving patient safety
Br. J. Anaesth., November 1, 2009; 103(5): 623 - 625.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.