British Journal of Anaesthesia, 2001, Vol. 86, No. 1 50-58
© 2001 The Board of Management and Trustees of the British Journal of Anaesthesia
Comparison of changes in electroencephalographic measures during induction of general anaesthesia: influence of the gamma frequency band and electromyogram signal
1Department of Anaesthesia, Waikato Hospital, Hamilton, New Zealand. 2Department of Physics and Medical Electronics, University of Waikato, Hamilton, New Zealand*Corresponding author
Recent research has shown that high-frequency, gamma-band electroencephalographic (EEG) oscillations (4060 Hz) may be an important marker of the conscious state. We compared the ability of the bispectral index (BIS) to distinguish the awake and anaesthetized states during the induction of general anaesthesia with: (i) components of the BIS (BetaRatio, SynchFastSlow); (ii) a new EEG variablethe median frequency of the first time derivative of the EEG signal (SE50d); and (iii) the SE50d derived from an EEG signal that has had the frequencies above 30 Hz removed (SE50d30Hz). Two groups of subjects were studied: (i) nine volunteers undergoing a short propofol infusion until loss of response to verbal command, and (ii) 84 patients undergoing routine anaesthesia for a variety of surgical procedures. In the volunteer group, the changes in the BetaRatio and SE50d were comparable with changes in the BIS. The changes in the SE50d30Hz were less consistent. In the patient group, the BIS components were equivalent to the BIS in separating the awake from the surgically anaesthetized states (area under receiver operating curve: BIS 0.95, SE50d 0.95, BetaRatio 0.96). Using the submental electromyogram (EMG) signal to estimate the frontalis EMG (3047 Hz) signal, the changes in EMG signal were, on average, about one-tenth the magnitude of the EEG. We conclude that: (i) there exist simpler derived EEG variables that are similar in accuracy to the BIS; (ii) it is important to avoid filtering out the EEG frequencies above 30 Hz; and (iii) in most patients the confounding effects of the frontalis EMG on the EEG are minimal.
Br J Anaesth 2001; 86: 508
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
A. G. Doufas, R. Komatsu, M. Orhan-Sungur, P. Sengupta, A. Wadhwa, E. Mascha, S. L. Shafer, and D. I. Sessler Neuromuscular Block Differentially Affects Immobility and Cortical Activation at Near-Minimum Alveolar Concentration Anesthesia Anesth. Analg., October 1, 2009; 109(4): 1097 - 1104. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. A. Dahaba, G. X. Xu, Q. H. Liu, J. X. Xue, and H. Metzler Bispectral Index Monitoring of a Narcolepsy-Cataplexy Episode During Regional Anesthesia Anesth. Analg., February 1, 2009; 108(2): 613 - 615. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kawaguchi, I. Takamatsu, K. Masui, and T. Kazama Effect of landiolol on bispectral index and spectral entropy responses to tracheal intubation during propofol anaesthesia Br. J. Anaesth., August 1, 2008; 101(2): 273 - 278. [Abstract] [Full Text] [PDF] |
||||
![]() |
A A Dahaba, H C Worm, S M Zhu, F P Bao, A Salah, S Zakaria, H Bornemann, V Stadlbauer, P H Rehak, H Metzler, et al. Sensitivity and specificity of bispectral index for classification of overt hepatic encephalopathy: a multicentre, observer blinded, validation study Gut, January 1, 2008; 57(1): 77 - 83. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Bonhomme and P. Hans Muscle relaxation and depth of anaesthesia: where is the missing link? Br. J. Anaesth., October 1, 2007; 99(4): 456 - 460. [Full Text] [PDF] |
||||
![]() |
A. Ekman, E. Stalberg, E. Sundman, L. I. Eriksson, L. Brudin, and R. Sandin The Effect of Neuromuscular Block and Noxious Stimulation on Hypnosis Monitoring During Sevoflurane Anesthesia Anesth. Analg., September 1, 2007; 105(3): 688 - 695. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. A. Dahaba, U. Lischnig, R. Kronthaler, H. Bornemann, V. Georgiev, P. H. Rehak, and H. Metzler Bispectral-index-guided versus clinically guided remifentanil/propofol analgesia/sedation for interventional radiological procedures: an observer-blinded randomized study. Anesth. Analg., August 1, 2006; 103(2): 378 - 84, table of contents. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Liu, T. Chazot, I. Huybrechts, J.-D. Law-Koune, L. Barvais, and M. Fischler The Influence of a Muscle Relaxant Bolus on Bispectral and Datex-Ohmeda Entropy Values During Propofol-Remifentanil Induced Loss of Consciousness Anesth. Analg., December 1, 2005; 101(6): 1713 - 1718. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. A. Dahaba Different Conditions That Could Result in the Bispectral Index Indicating an Incorrect Hypnotic State Anesth. Analg., September 1, 2005; 101(3): 765 - 773. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. A. Dahaba, M. Mattweber, A. Fuchs, W. Zenz, P. H. Rehak, W. F. List, and H. Metzler The Effect of Different Stages of Neuromuscular Block on the Bispectral Index and the Bispectral Index-XP Under Remifentanil/Propofol Anesthesia Anesth. Analg., September 1, 2004; 99(3): 781 - 787. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Morimoto, S. Hagihira, Y. Koizumi, K. Ishida, M. Matsumoto, and T. Sakabe The Relationship Between Bispectral Index and Electroencephalographic Parameters During Isoflurane Anesthesia Anesth. Analg., May 1, 2004; 98(5): 1336 - 1340. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Miller, J. W. Sleigh, J. Barnard, and D. A. Steyn-Ross Does bispectral analysis of the electroencephalogram add anything but complexity?{dagger} Br. J. Anaesth., January 1, 2004; 92(1): 8 - 13. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Gurses, H. Sungurtekin, E. Tomatir, and H. Dogan Assessing Propofol Induction of Anesthesia Dose Using Bispectral Index Analysis Anesth. Analg., January 1, 2004; 98(1): 128 - 131. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Hagihira, M. Takashina, T. Mori, T. Mashimo, and I. Yoshiya Practical Issues in Bispectral Analysis of Electroencephalographic Signals Anesth. Analg., October 1, 2001; 93(4): 966 - 970. [Abstract] [Full Text] [PDF] |
||||