Skip Navigation

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Farmery, A. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Farmery, A. D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 2000, Vol. 85, No. 6 917-919
© 2000 The Board of Management and Trustees of the British Journal of Anaesthesia

Severe unilateral bronchospasm mimicking inadvertent endobronchial intubation: a complication of the use of a topical lidocaine Laryngojet injector

A. D. Farmery

Nuffield Department of Anaesthetics, University of Oxford, Radcliffe Infirmary, Oxford OX2 6HE, UK

A healthy young woman is described in whom the left chest was unable to be inflated after intubation. The differential diagnosis and management are discussed. Severe unilateral bronchospasm was probably caused by topical lidocaine injected at the vocal cords and, inadvertently, into the left main bronchus with a Laryngojet device.

Br J Anaesth 2000; 85: 917–19.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
R. K. Visaria and D. R. Westenskow
Model-Based Detection of Endobronchial Intubation
Anesth. Analg., October 1, 2006; 103(4): 888 - 893.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.