British Journal of Anaesthesia, 2000, Vol. 84, No. 6 749-752
© 2000 Oxford University Press
Clinical Investigation |
Fentanyl and midazolam anaesthesia for coronary bypass surgery: a clinical study of bispectral electroencephalogram analysis, drug concentrations and recall
1 Department of Cardiothoracic Anaesthetics and Intensive Care, Karolinska Hospital, Stockholm, Sweden.
2 Department of Anaesthetics, Sabbatsbergs Hospital, Stockholm, Sweden
Abstract
Bispectral index (BIS) was assessed as a monitor of depth of anaesthesia during fentanyl and midazolam anaesthesia for coronary bypass surgery. In 10 patients given morphine premedication, anaesthesia was induced with a combination of midazolam and fentanyl and thereafter maintained with a continuous infusion of a mixture of midazolam and fentanyl 5 and 50 µg kg1 h1, respectively. BIS was recorded continuously but not shown to the attending anaesthetist. Plasma concentrations of midazolam and fentanyl were measured five times during the procedure. An auditory stimulus was given during bypass. All patients were interviewed twice after operation for explicit and implicit recall. No patient had any anaesthetic complications. BIS decreased during anaesthesia, but varied considerably during surgery (range 3691) with eight patients having values >60. Midazolam and fentanyl drug concentrations did not correlate with BIS. No patient reported explicit or implicit recall. During clinically adequate anaesthesia with midazolam and fentanyl BIS varies considerably. The most likely reason is that BIS is not an accurate measure of the depth of anaesthesia when using this combination of agents.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
S. Sadhasivam, A. Ganesh, A. Robison, R. Kaye, and M. F. Watcha Validation of the Bispectral Index Monitor for Measuring the Depth of Sedation in Children Anesth. Analg., February 1, 2006; 102(2): 383 - 388. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. K. Tempe and L. Satyanarayana Editorial I: Is there any alternative to the Bispectral Index Monitor? Br. J. Anaesth., January 1, 2004; 92(1): 1 - 3. [Full Text] [PDF] |
||||
![]() |
M. E. McCann, R. M. Brustowicz, J. Bacsik, L. Sullivan, S. G. Auble, and P. C. Laussen The Bispectral Index and Explicit Recall During the Intraoperative Wake-up Test for Scoliosis Surgery Anesth. Analg., June 1, 2002; 94(6): 1474 - 1478. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Schmidlin, P. Hager, and E. R. Schmid Monitoring level of sedation with bispectral EEG analysis: comparison between hypothermic and normothermic cardiopulmonary bypass{{dagger}} Br. J. Anaesth., June 1, 2001; 86(6): 769 - 776. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. K. Tempe In Search of a Reliable Awareness Monitor Anesth. Analg., April 1, 2001; 92(4): 801 - 804. [Full Text] [PDF] |
||||