British Journal of Anaesthesia, Vol 82, Issue 6 920-921, Copyright © 1999 by The Board of Management and Trustees of the British Journal of Anaesthesia
K. F. Cheong and K. F. Koh
We have compared a new intubation manoeuvre using a fibreoptic bronchoscope
with conventional blind placement of a double-lumen tube. Thirty adult
patients who presented for thoracoscopy requiring one-lung ventilation
underwent endobronchial intubation with a double-lumen tube inserted either
in the conventional blind way or using a fibreoptic bronchoscope. There
were four misplacements of the double-lumen tube using the conventional
method but none using the bronchoscope. In addition, the bronchoscope
allowed more rapid intubation (mean 106 vs 347 s). The results suggest that
the fibreoptic-guided method of inserting the double-lumen tube was a
satisfactory alternative to the conventional one.
SHORT COMMUNICATIONS
Placement of left-sided double-lumen endobronchial tubes: comparison of clinical and fibreoptic-guided placement
Department of Anaesthesia, National University Hospital, 5 Lower Kent Ridge Road, Singapore 119074
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
R. R. Al-Metwalli, H. A. Mowafi, and S. A. Ismail Double-Lumen Tube Placement Using a Retractable Carinal Hook: A Preliminary Report Anesth. Analg., August 1, 2009; 109(2): 447 - 450. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Pfitzner, M. J. Peacock, E. Tsirgiotis, and I. H. Walkley Lobectomy for cavitating lung abscess with haemoptysis: strategy for protecting the contralateral lung and also the non-involved lobe of the ipsilateral lung Br. J. Anaesth., November 1, 2000; 85(5): 791 - 794. [Abstract] [Full Text] [PDF] |
||||