Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (45)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Verghese, C.
Right arrow Articles by Pollard, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Verghese, C.
Right arrow Articles by Pollard, R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, Vol 80, Issue 5 677-679, Copyright © 1998 by The Board of Management and Trustees of the British Journal of Anaesthesia


SHORT COMMUNICATIONS

Clinical assessment of the single use laryngeal mask airway--the LMA- unique

C. Verghese, J. Berlet, A. Kapila and R. Pollard
Research Centre, Department of Anaesthesia, Royal Berkshire Hospital, Reading RG1 5AN.

We conducted a clinical comparison of the laryngeal mask airway (LMA) and the new single use PVC LMA (LMA-Unique) in 100 fasted adult patients undergoing elective surgery. Patients were allocated to one of two groups: group 1 (n = 50) was managed by two consultants and group 2 by two trainee anaesthetists. Airway management was randomized prospectively within each group, and cuff pressure in both devices was maintained at a maximum of 50 mm Hg with upward size substitution if leaks persisted during intermittent positive pressure ventilation (IPPV). Insertion with the recommended technique was successful in all patients (85 first attempt). One patient (group 1) required four attempts for insertion of the LMA-Unique and in one patient (group 2) the LMA-Unique was replaced by a tracheal tube because of persistent leaks during IPPV. In 99 patients IPPV was uneventful. The adjusted mean volume of air for cuff inflation in the LMA-Unique was significantly less in group 1 (P = 0.0013). At fibreoptic laryngoscopic examination, the vocal cords or arytenoids, or both, could be seen in 92% of patients in group 1 and in 90% of patients in group 2. Immediate throat soreness was reported in four patients in group 1 and in seven in group 2. The results suggest that the LMA-Unique was similar in clinical performance to the LMA.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
R. Mihai, G. Knottenbelt, and T. M. Cook
Evaluation of the revised laryngeal tube suction: the laryngeal tube suction II in 100 patients
Br. J. Anaesth., November 1, 2007; 99(5): 734 - 739.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. Lange, T. Smul, P. Zimmermann, R. Kohlenberger, N. Roewer, and F. Kehl
The Effectiveness and Patient Comfort of the Novel Streamlined Pharynx Airway Liner (SLIPA(R)) Compared with the Conventional Laryngeal Mask Airway in Ophthalmic Surgery
Anesth. Analg., February 1, 2007; 104(2): 431 - 434.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
L. Gaitini and D. Alfery
Comparison Between the PLA CobraTM and the Laryngeal Mask Airway UniqueTM: Choice of Laryngeal Mask Airway Unique Size
Anesth. Analg., February 1, 2007; 104(2): 458 - 458.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
T. M. Cook, M. Asif, R. Sim, and J. Waldron
Use of a ProSealTM laryngeal mask airway and a Ravussin cricothyroidotomy needle in the management of laryngeal and subglottic stenosis causing upper airway obstruction
Br. J. Anaesth., October 1, 2005; 95(4): 554 - 557.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
T. M. Cook and J. Cranshaw
Randomized crossover comparison of ProSeal(R) Laryngeal Mask Airway with Laryngeal Tube Sonda(R) during anaesthesia with controlled ventilation
Br. J. Anaesth., August 1, 2005; 95(2): 261 - 266.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
E. M. Walsh
Time to Dispose of Nondisposable LMAs
Anesth. Analg., March 1, 2005; 100(3): 896 - 897.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
J. Brimacombe, A. von Goedecke, C. Keller, L. Brimacombe, and M. Brimacombe
The Laryngeal Mask Airway UniqueTM versus the Soft SealTM Laryngeal Mask: A Randomized, Crossover Study in Paralyzed, Anesthetized Patients
Anesth. Analg., November 1, 2004; 99(5): 1560 - 1563.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
T. M. Cook and M. V. Porter
Randomized comparison of the classic Laryngeal Mask AirwayTM with the Airway Management DeviceTM during anaesthesia
Br. J. Anaesth., November 1, 2003; 91(5): 672 - 677.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
T. M. Cook, C. McKinstry, R. Hardy, and S. Twigg
Randomized crossover comparison of the ProSealTM laryngeal mask airway with the Laryngeal Tube(R) during anaesthesia with controlled ventilation
Br. J. Anaesth., November 1, 2003; 91(5): 678 - 683.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.