Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (9)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Kiyama, S.
Right arrow Articles by Tsuzaki, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kiyama, S.
Right arrow Articles by Tsuzaki, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, Vol 78, Issue 6 751-753, Copyright © 1997 by The Board of Management and Trustees of the British Journal of Anaesthesia


SHORT COMMUNICATIONS

Processed electroencephalogram during combined extradural and general anaesthesia

S. Kiyama and K. Tsuzaki
Department of Anaesthesia, Shizuoka Red Cross Hospital, 8-2 Ohtemachi, Shizuoka 420, Japan; Department of Anaesthesia, Keio University, School of Medicine, 35 Shinanomachi, Tokyo 160, Japan

The processed electroencephalogram (pEEG) was monitored in eight patients undergoing gynaecological laparotomy under combined extradural and nitrous oxide-isoflurane anaesthesia. Pre-incisional mean spectral edge frequency 95 percentile (SEF95) and median frequency (MF) were 11.67 (SD 1.63) Hz and 3.74 (0.24) Hz, respectively. After skin incision, both SEF95 and MF decreased to 6.61 (2.04) Hz and 2.72 (0.32) Hz, respectively (P < 0.001). An increase in mean arterial pressure after incision suggested inadequate depth of anaesthesia. After introduction of extradural analgesia, these variables returned to pre- incisional values (SEF95 11.65 (1.73); MF 4.02 (0.41)). Reduction of end-tidal isoflurane from 1.0% to 0.5% after extradural analgesia did not cause significant pEEG changes. pEEG may assist anaesthetists to recognize adequacy of combined general-extradural anaesthesia.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
A. P. Morley, J. Derrick, P. T. Seed, P. E. Tan, D. C. Chung, and T. G. Short
Isoflurane Dosage for Equivalent Intraoperative Electroencephalographic Suppression in Patients With and Without Epidural Blockade
Anesth. Analg., November 1, 2002; 95(5): 1412 - 1418.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.