Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (25)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Vercauteren, M. P.
Right arrow Articles by Adriaensen, H. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vercauteren, M. P.
Right arrow Articles by Adriaensen, H. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, Vol 76, Issue 5 731-733, Copyright © 1996 by The Board of Management and Trustees of the British Journal of Anaesthesia


SHORT COMMUNICATIONS

Hydroxyethylstarch compared with modified gelatin as volume preload before spinal anaesthesia for Caesarean section

M. P. Vercauteren, V. Hoffmann, H. C. Coppejans, A. L. Van Steenberge and H. A. Adriaensen
Department of Anaesthesiology, University Hospital Antwerp, Wilrijkstraat 10, B-2650 Edegem, Belgium

We studied 90 patients undergoing elective Caesarean section under spinal anaesthesia who received lactated Ringer's solution 1000 ml with up to 1000 ml of modified gelatin, lactated Ringer's solution 1000 ml with up to 1000 ml of 6% hydroxyethylstarch or only up to 1000 ml of 6% hydroxyethylstarch. Lumbar puncture was performed as soon as 500 ml of the colloid were infused. The incidence of hypotension, number of patients requiring a vasopressor and doses of ephedrine required to restore arterial pressure were significantly lower in favour of those receiving the crystalloid-hydroxyethylstarch combination. In both groups receiving the 2000 ml preload, packed cell volume (PCV) values decreased by more than 20%, which may be of concern in patients already presenting with mild anaemia. In patients who received the colloid without the crystalloid, PCV values decreased by 14% but the risk of severe hypotension was comparable with the crystalloid-gelatin combination.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
S. M. Siddik-Sayyid, V. G. Nasr, S. K. Taha, R. A. Zbeide, J.-M. A. Shehade, A. A. Al Alami, F. H. Mokadem, F. W. Abdallah, A. S. Baraka, and M. T. Aouad
A Randomized Trial Comparing Colloid Preload to Coload During Spinal Anesthesia for Elective Cesarean Delivery
Anesth. Analg., October 1, 2009; 109(4): 1219 - 1224.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. Van de Velde, D. Van Schoubroeck, J. Jani, A. Teunkens, C. Missant, and J. Deprest
Combined spinal-epidural anesthesia for cesarean delivery: dose-dependent effects of hyperbaric bupivacaine on maternal hemodynamics.
Anesth. Analg., July 1, 2006; 103(1): 187 - 190.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
H. C. Coppejans, E. Hendrickx, J. Goossens, and M. P. Vercauteren
The Sitting Versus Right Lateral Position During Combined Spinal-Epidural Anesthesia for Cesarean Delivery: Block Characteristics and Severity of Hypotension
Anesth. Analg., January 1, 2006; 102(1): 243 - 247.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. P. Vercauteren, H. C. Coppejans, and L. Sermeus
Anaphylactoid Reaction to Hydroxyethylstarch During Cesarean Delivery in a Patient with HELLP Syndrome
Anesth. Analg., March 1, 2003; 96(3): 859 - 861.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
P. J. Morgan, S. H. Halpern, and J. Tarshis
The Effects of an Increase of Central Blood Volume Before Spinal Anesthesia for Cesarean Delivery: A Qualitative Systematic Review
Anesth. Analg., April 1, 2001; 92(4): 997 - 1005.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
P. J. Sarvela, P. M. Halonen, and K. T. Korttila
Comparison of 9 mg of Intrathecal Plain and Hyperbaric Bupivacaine Both with Fentanyl for Cesarean Delivery
Anesth. Analg., November 1, 1999; 89(5): 1257 - 1257.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.