Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (81)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by NEWTON, D. E. F.
Right arrow Articles by DORE, C. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by NEWTON, D. E. F.
Right arrow Articles by DORE, C. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 1992, Vol. 69, No. 2 122-129
© 1992 The Board of Management and Trustees of the British Journal of Anaesthesia


research-article

AUDITORY EVOKED RESPONSE AND AWARENESS: A STUDY IN VOLUNTEERS AT SUB-MAC CONCENTRATIONS OF ISOFLURANE

D. E. F. NEWTON, M.B., B.S., F.R.C.ANAES.1,*, C. THORNTON, M.SC, PH.D.1, K. M. KONIECZKO, M.B., B.S., F.R.C.ANAES.1, C. JORDAN, M.SC, B.TECH.1, N. R. WEBSTER, B.SC., M.B., CH.B., PH.D., F.R.C.ANAES.1, N. P. LUFF, B.SC.1, C. D. FRITH, M.A., PH.D, DIP.PSYCH.2 and C. J. DORE, B.SC.3

1Division of Anaesthesia, Clinical Research Centre Watford Road, Harrow, Middlesex HA1 3UJ
2Division of Psychiatry, Clinical Research Centre Watford Road, Harrow, Middlesex HA1 3UJ
3Section of Medical Statistics, Clinical Research Centre Watford Road, Harrow, Middlesex HA1 3UJ

*Address for correspondence: Anaesthetic Research Unit, Northwick Park Hospital, Watford Road, Harrow, Middlesex HA1 3UJ.

We have investigated the relationship between the auditory evoked response (AER) and simple tests of conscious awareness at four end-expiratory concentrations (0.0. 0.1. 0.2 and 0.4 MAC) of iso-flurane in oxygen in each of eight anaesthetist volunteers, in random order, at least 1 week apart. The early cortical AER was recorded from electrodes at the vertex and inion. Amplitudes of the waves Pa, Nb and Pc and latencies of the waves Na, Pa, Nb, Pb and Nc were measured. All the AER variables were highly significantly related to end-expiratory anaesthetic concentration. Amplitudes decreased and latencies increased progressively with increasing anaesthetic concentration. The AER variables were also highly significantly related to the level of response. Amplitudes were greatest and the latencies shortest when there was full response to command. (Nb latency increased from 47.5 to 54.5 ms between partial and no response.) The close correlation between the effects of concentration and level of response, and between concentration and the AER implied that it was difficult to demonstrate those changes in the AER which specifically relate to changes in response. At 0.2 MAC, however, which was the concentration at which all subjects showed some deficit, the response to a shock word was distinguished clearly by Nb latency. In eight of 24 possible comparisons (eight AER variables and three types of psychological test) the AER fitted the response more closely than concentration.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
P. Szmuk, N. Aroyo, T. Ezri, G. Muzikant, M. Weisenberg, and D. I. Sessler
Listening to Music During Anesthesia Does Not Reduce the Sevoflurane Concentration Needed to Maintain a Constant Bispectral Index
Anesth. Analg., July 1, 2008; 107(1): 77 - 80.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
I. Wenningmann, S. Paprotny, S. Strassmann, R. K. Ellerkmann, B. Rehberg, M. Soehle, and B.W. Urban
Correlation of the A-LineTM ARX index with acoustically evoked potential amplitude
Br. J. Anaesth., November 1, 2006; 97(5): 666 - 675.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
C. D. Hanning
Postoperative cognitive dysfunction
Br. J. Anaesth., July 1, 2005; 95(1): 82 - 87.
[Full Text] [PDF]


Home page
Br Med BullHome page
R. D. Sanders, D. Ma, and M. Maze
Xenon: elemental anaesthesia in clinical practice
Br. Med. Bull., February 22, 2005; 71(1): 115 - 135.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
A. J. Clapcich, R. G. Emerson, D. P. Roye Jr., H. Xie, E. J. Gallo, K. C. Dowling, B. Ramnath, and E. J. Heyer
The Effects of Propofol, Small-Dose Isoflurane, and Nitrous Oxide on Cortical Somatosensory Evoked Potential and Bispectral Index Monitoring in Adolescents Undergoing Spinal Fusion
Anesth. Analg., November 1, 2004; 99(5): 1334 - 1340.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
R. A. Rodriguez
Human Auditory Evoked Potentials in the Assessment of Brain Function During Major Cardiovascular Surgery
Seminars in Cardiothoracic and Vascular Anesthesia, June 1, 2004; 8(2): 85 - 99.
[Abstract] [PDF]


Home page
Anesth. Analg.Home page
B. Migneault, F. Girard, C. Albert, P. Chouinard, D. Boudreault, D. Provencher, A. Todorov, M. Ruel, and D. C. Girard
The Effect of Music on the Neurohormonal Stress Response to Surgery Under General Anesthesia
Anesth. Analg., February 1, 2004; 98(2): 527 - 532.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
M. A. Tooley, C. L. Stapleton, G. L. Greenslade, and C. Prys-Roberts
Mid-latency auditory evoked response during propofol and alfentanil anaesthesia
Br. J. Anaesth., January 1, 2004; 92(1): 25 - 32.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
R. D. Sanders, N. P. Franks, and M. Maze
Xenon: no stranger to anaesthesia
Br. J. Anaesth., November 1, 2003; 91(5): 709 - 717.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
I. Rundshagen, K. Schnabel, and J. Schulte am Esch
Midlatency auditory evoked potentials do not allow the prediction of recovery from general anesthesia with isoflurane: [Les potentiels evoques auditifs de milatence ne permettent pas de predire la recuperation apres une anesthesie generale a l'isoflurane]
Can J Anesth, April 1, 2002; 49(4): 361 - 368.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. Nemethy, L. Paroli, P. G. Williams-Russo, and T. J. J. Blanck
Assessing Sedation with Regional Anesthesia: Inter-Rater Agreement on a Modified Wilson Sedation Scale
Anesth. Analg., March 1, 2002; 94(3): 723 - 728.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
E. Loveman, J. C. Van Hooff, and D. C. Smith
The auditory evoked response as an awareness monitor during anaesthesia
Br. J. Anaesth., April 1, 2001; 86(4): 513 - 518.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
R. C. Dutton, I. J. Rampil, and E. I Eger II
Inhaled Nonimmobilizers Do Not Alter the Middle Latency Auditory-Evoked Response of Rats
Anesth. Analg., January 1, 2000; 90(1): 213 - 213.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. Schraag, U. Bothner, R. Gajraj, G. N. C. Kenny, and M. Georgieff
The Performance of Electroencephalogram Bispectral Index and Auditory Evoked Potential Index to Predict Loss of Consciousness During Propofol Infusion
Anesth. Analg., November 1, 1999; 89(5): 1311 - 1311.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
E. Kochs, C. J. Kalkman, C. Thornton, D. Newton, P. Bischoff, H. Kuppe, J. Abke, E. Konecny, W. Nahm, and G. Stockmanns
Middle Latency Auditory Evoked Responses and Electroencephalographic Derived Variables Do Not Predict Movement to Noxious Stimulation During 1 Minimum Alveolar Anesthetic Concentration Isoflurane/Nitrous Oxide Anesthesia
Anesth. Analg., June 1, 1999; 88(6): 1412 - 1412.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
J G Jones
Memory of intraoperative events
BMJ, October 15, 1994; 309(6960): 967 - 968.
[Full Text]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.