Skip Navigation


BJA Advance Access originally published online on February 3, 2009
British Journal of Anaesthesia 2009 102(3):424-430; doi:10.1093/bja/aep002
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
102/3/424    most recent
aep002v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Wong, D. M.
Right arrow Articles by Cooper, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wong, D. M.
Right arrow Articles by Cooper, R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Board of Management and Trustees of the British Journal of Anaesthesia 2009. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Cervical spine motion during flexible bronchoscopy compared with the Lo-Pro GlideScope®

D. M. Wong1,5,*, A. Prabhu1, S. Chakraborty2, G. Tan3, E. M. Massicotte3 and R. Cooper4

1 Department of Anaesthesia
2 Department of Radiology
3 Department of Neurosurgery, Toronto Western Hospital, Canada
4 Department of Anaesthesia, Toronto General Hospital, Canada

* Corresponding author: PO Box 741, South Melbourne, VIC 3205, Australia. E-mail: danielm.ywong{at}gmail.com

Background: The most appropriate device for tracheal intubation in patients with potential cervical spine injury remains controversial. We hypothesized that the Lo-Pro GlideScope® (LP-G) videolaryngoscope would not cause significantly greater cervical spine movement than fibreoptic bronchoscopy even in the non-immobilized spine.

Methods: Twenty-eight healthy adults requiring intubation for radiographic procedures were randomized to either the LP-G or the flexible bronchoscope (FB) devices. Continuous fluoroscopy was used to assess cervical spine movement during tracheal intubation. The point of maximum movement was compared with baseline for change in angulation between Occiput (Occ)-C1, Occ-C2, Occ-C4, Occ-C5, C1–2, C2–4, and C4–5. Measurements were made by two independent observers. The change in angulation was also measured for tongue pull and jaw thrust, manoeuvres for enlarging the pharyngeal space, before FB intubation.

Results: LP-G resulted in greater cervical extension compared with FB for every angle calculated, statistically significant between Occ-C1 (P<0.05), Occ-C2 (P<0.05), and Occ-C4 (P<0.01). Tongue pull resulted in significantly less cervical spine motion than FB intubation at Occ-C1, Occ-C2, Occ-C4, and Occ-C5 (P<0.05). When jaw thrust was added to tongue pull, there was a tendency for greater movement than FB intubation at Occ-C1, Occ-C2, and Occ-C3. This was statistically significant at Occ-C1 and Occ-C3 (P<0.05) for one of the two observers.

Conclusions: During intubation under general anaesthesia, LP-G resulted in greater cervical movement than FB when no cervical immobilization was used in adults without cervical disease. Airway manoeuvres performed before FB, especially jaw thrust, also resulted in cervical spine movement.

Keywords: airway; anaesthetic techniques, bronchoscopy; anaesthetic techniques, laryngoscopy; equipment, laryngoscopes fibreoptic; monitoring, radiological


5 Present address: Department of Anaesthesia, St Vincent’s Hospital, Melbourne, Australia


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.