Skip Navigation

British Journal of Anaesthesia 2009 102(1):128-134; doi:10.1093/bja/aen342
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Malik, M. A.
Right arrow Articles by Laffey, J. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Malik, M. A.
Right arrow Articles by Laffey, J. G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Board of Management and Trustees of the British Journal of Anaesthesia 2009. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Comparison of the Glidescope®, the Pentax AWS®, and the Truview EVO2® with the Macintosh laryngoscope in experienced anaesthetists: a manikin study

M. A. Malik1,2, C. O'Donoghue1, J. Carney1,2, C. H. Maharaj1,2, B. H. Harte1,3 and J. G. Laffey1,2,3,*

1 Department of Anaesthesia, Galway University Hospitals, Galway, Ireland
2 Clinical Research Facility, National University of Ireland, Galway, Ireland
3 Department of Anaesthesia, Sligo General Hospital, Sligo, Ireland

* Corresponding author: Department of Anaesthesia, Clinical Sciences Institute, National University of Ireland, Galway, Ireland. E-mail: john.laffey{at}nuigalway.ie

Background: The Pentax Airwayscope®, the Glidescope®, and the Truview EVO2® constitute three novel laryngoscopes that facilitate visualization of the vocal cords without alignment of the oral, pharyngeal, and tracheal axes. We compared these devices with the Macintosh laryngoscope in a simulated easy and difficult laryngoscopy.

Methods: Thirty-five experienced anaesthetists were allowed up to three attempts to intubate in each of four laryngoscopy scenarios in a Laerdal® SimMan® manikin. The time required to perform tracheal intubation, the success rate, number of intubation attempts and of optimization manoeuvres, and the severity of dental compression were recorded.

Results: In the simulated easy laryngoscopy scenarios, there was no difference between the study devices and the Macintosh in success of tracheal intubation. In more difficult tracheal intubation scenarios, the Glidescope® and Pentax AWS®, and to a lesser extent the Truview EVO2® laryngoscope demonstrated advantages over the Macintosh laryngoscope including a better view of the glottis, greater success of tracheal intubation, and ease of device use. The Pentax AWS® was more successful in achieving tracheal intubation, required less time to successfully perform tracheal intubation, caused less dental trauma, and was considered by the anaesthetists to be easier to use.

Conclusions: The Pentax AWS® laryngoscope demonstrated more advantages over the Macintosh laryngoscope than either the Truview EVO2® or the Glidescope® laryngoscope, when used by experienced anaesthetists in difficult tracheal intubation scenarios.

Keywords: equipment, Pentax AWS® laryngoscope, Glidescope® laryngoscope, Truview EVO2® laryngoscope, Macintosh laryngoscope, manikin; intubation, tracheal, difficult intubation


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
L. Powell, J. Andrzejowski, R. Taylor, and D. Turnbull
Comparison of the performance of four laryngoscopes in a high-fidelity simulator using normal and difficult airway
Br. J. Anaesth., November 1, 2009; 103(5): 755 - 760.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
M. A. Malik, R. Subramaniam, C. H. Maharaj, B. H. Harte, and J. G. Laffey
Randomized controlled trial of the Pentax AWS(R), Glidescope(R), and Macintosh laryngoscopes in predicted difficult intubation
Br. J. Anaesth., November 1, 2009; 103(5): 761 - 768.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
E. H. C. Liu, R. W. L. Goy, B. H. Tan, and T. Asai
Tracheal intubation with videolaryngoscopes in patients with cervical spine immobilization: a randomized trial of the Airway Scope(R) and the GlideScope(R)
Br. J. Anaesth., September 1, 2009; 103(3): 446 - 451.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
F. Martin and D. J. Buggy
New airway equipment: opportunities for enhanced safety
Br. J. Anaesth., June 1, 2009; 102(6): 734 - 738.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
M. A. Malik, R. Subramaniam, S. Churasia, C. H. Maharaj, B. H. Harte, and J. G. Laffey
Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope(R), LMA CTrach(R), and the Macintosh laryngoscopes
Br. J. Anaesth., May 1, 2009; 102(5): 654 - 661.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.