Skip Navigation



BJA Advance Access published online on September 14, 2007

British Journal of Anaesthesia, doi:10.1093/bja/aem262
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
99/5/662    most recent
aem262v1
Right arrow E-Letters: Submit a response to the article
Right arrow E-letters: View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Wigmore, T. J.
Right arrow Articles by MacCallum, N. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wigmore, T. J.
Right arrow Articles by MacCallum, N. S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Board of Management and Trustees of the British Journal of Anaesthesia 2007. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Effect of the implementation of NICE guidelines for ultrasound guidance on the complication rates associated with central venous catheter placement in patients presenting for routine surgery in a tertiary referral centre

T. J. Wigmore1,*, J. F. Smythe2, M. B. Hacking1, R. Raobaikady1 and N. S. MacCallum1

1 Department of Anaesthesia, The Royal Marsden NHS Foundation Trust, London, UK
2 Department of Anaesthetics, Pain Medicine and Intensive Care, Division of Surgery, Oncology, Reproductive Biology and Anaesthetics, Imperial College London, Chelsea and Westminster NHS Foundation Trust, London, UK

* Corresponding author. E-mail: timothy.wigmore{at}rmh.nhs.uk

Accepted for publication June 17, 2007.


    Abstract
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Acknowledgement
 References
 
Background: The National Institute for Clinical Excellence (NICE) guidelines of 2002 recommended the use of ultrasound (US) for central venous catheterization in order to minimize complications associated with central line placement. An ongoing audit of line placement by anaesthetists in the theatre complex of a tertiary referral centre looked at the associated complication rates. The objective of the study was to compare complication rates pre- and post-implementation of NICE guidelines.

Methods: This prospective, single centre audit looked at all patients in whom a central venous catheter was placed for surgery. Complication rates were assessed for procedures that were performed pre- and post-implementation of NICE guidelines. In total, 438 patients were identified for the study, and the procedures were performed either by trainee or by consultant anaesthetists.

Results: The pre- and post-implementation complication rates were 10.5% (16/152) and 4.6% (13/284), respectively, representing an absolute risk reduction of 5.9% (95% CI 0.5–11.3%). Comparison of those procedures in which US was used when compared with the landmark technique after implementation found a reduction of 6.9% in complications (95% CI 1.4–12.4%). The reduction in complication rates was larger for specialist registrars than for consultants (11.2% vs 1.6%).

Conclusions: The implementation of NICE guidelines has been associated with a significant reduction in complication rates in our tertiary referral centre. In the light of the cross-speciality evidence of US superiority and our results, it is imperative that routine use of US guidance becomes more widespread.

Keywords: complications, catheter misplacement; complications, pneumothorax; equipment, cannulae intravascular; lung, pneumothorax; measurement techniques, ultrasound; monitoring, ultrasound; surgery, preoperative, non-cardiac; veins, complications, cannulation, jugular, jugular, cannulation, venepuncture


    Introduction
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Acknowledgement
 References
 
The National Institute for Clinical Excellence (NICE) guidelines formulated in September 2002 and reviewed in August 2005 recommended two-dimensional imaging ultrasound (US) guidance as the preferred method of both elective and emergency central venous cannulations.1 A commissioned meta-analysis by NICE including 18 randomized control trials comparing US with the landmark method for central venous access concluded that US was more effective than landmark for all outcomes for cannulation of the internal jugular vein, and the relative risks of failed attempts, complications, and failed first attempts were 86%, 57%, and 41%, respectively.2 3

Complications of central venous cannulation include arterial puncture, pneumothorax, neck or mediastinal haematoma, and haemothorax.4 5 US has been shown to decrease all of these in a series of individual studies and in two meta-analyses. It has also been shown to decrease time to cannulation and the number of attempts.46 The superiority of US over the landmark method has been demonstrated in a range of clinical settings, including paediatrics,79 renal medicine,10 11 intensive care,12 13 and the emergency department.14 15 However, there are surprisingly few studies involving anaesthetists or patients presenting for routine surgery.

The uptake of NICE guidelines across the UK has been variable and inconsistent16 and to our knowledge ours is the first study to date that has looked at the impact of implementation of these guidelines and the direct effects on complication rates. Our tertiary referral centre has had an ongoing audit looking at complications associated with central venous cannulation since February 2005, and results before introduction of routine US guidance in October 2005 showed a complication rate of 10.5% (16/152).


    Methods
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Acknowledgement
 References
 
Study design
This was a prospective audit performed in the theatre complex of a tertiary referral centre. The protocol was approved by our audit committee before commencement of the study and was discussed with the Chair of the research ethics committee who stated that ethics committee approval was not required.

Selection of participants
All patients older than 18 yr presenting for surgery between October 2005 and November 2006 who required central venous access as part of their anaesthetic were included. The patient population represented a heterogeneous group with advanced malignancies and often had risk factors for difficult cannulation.

Interventions
All central venous cannulations were performed by senior specialist registrars (post-fellowship SpRs in Anaesthesia) or consultant anaesthetists. In line with NICE guidance, the choice of whether to use the landmark technique or US guidance was left to the operator.

Ultrasonic guidance was with the portable SonoSiteTM (SonoSite Inc., Bothell, WA, USA) iLook25 with a 10–5 MHz linear array. Insertion was performed aseptically with the probe being covered by a sterile sleeve and gel. Training was provided by Trust Anaesthetic consultants who had been on the SonoSiteTM vascular access course.

The landmark technique was performed aseptically according to operator experience and preference.

Chest radiographs were reviewed after each procedure, and assessment of incorrect positioning and associated complications was made.

Data collection
For each attempted cannulation, operator (consultant or SpR), site (internal jugular, left or right side), method of insertion, complications (with exact details), and number of attempts were documented on a pre-printed data collection sheet.

Complications were defined as arterial puncture, pneumothorax, haematoma, and other.

The insertion was deemed a failure if the operator was unable to cannulate the first site attempted or had to change technique.

Statistical analysis
Results were analysed with SPSS v12.0 (SPSS Inc., Chicago, IL, USA). Analyses were conducted using the {chi}2 test and confidence intervals for difference were calculated using the continuity corrected Wald confidence interval.


    Results
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Acknowledgement
 References
 
In total, 284 insertions were performed in the 13 month period after implementation of the guidelines. 169 (59.5%) were conducted using US guidance and 115 (41.5%) with the landmark technique.

Table 1 summarizes the main outcome measures. Consultants (42.1% and 44.4%) and SpRs (57.9% and 55.6%) inserted a similar proportion of central venous catheters (CVCs) before and after implementation of guidelines. All lines were placed in the internal jugular vein.


View this table:
[in this window]
[in a new window]

 
Table 1 Main outcome measures pre- and post-implementation of NICE guidelines. *In eight cases, both SpR and consultant attempted insertion on the same patient

 
The overall uptake rate of US guidance after implementation was 59.5% (60.3% for consultants and 62.0% for SpRs). Uptake increased markedly as the audit progressed (Fig. 1).


Figure 1
View larger version (7K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Fig 1 Ongoing percentage uptake of US guidance after guideline implementation. Calculated at patient number n as [number of times ultrasound used from case (n–50...n)]/50.

 
There were 19/152 complications during the pre-guideline audit (18 of which involved the landmark technique) and 13/286 complications after. Ten of these were in the landmark group (8.7% complication rate) and three were in the US-guided group (1.7% complication rate). This is an absolute risk reduction in favour of US of 6.9% (95% CI 1.4–12.4%). There were five carotid artery punctures, one pneumothorax, and four haematomas in the landmark group. In the US group, there were three carotid artery punctures.

Table 2 compares the incidence of complications for SpRs and consultants with and without US guidance. It can be seen that in our institution the positive effect is most marked for SpRs (12.3% vs 1.1% complication rate, an absolute risk reduction (ARR) of 11.2%, 95% CI 2.9–19.5%).


View this table:
[in this window]
[in a new window]

 
Table 2 Comparison of the failure and complication rates for the landmark technique and US guidance after guideline implementation

 
There was a significantly greater number of failed insertions in the landmark technique group (7/115 vs 1/169, P < 0.01). In five of the cases of failed insertion using the landmark technique, US was used successfully in further attempts. However, we did not demonstrate any difference in the average number of attempts to successful cannulation.


    Discussion
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Acknowledgement
 References
 
The insertion of CVCs is a common practice that is associated with significant morbidity.5 There is increasing cross-speciality evidence for the superiority of US guidance in central venous cannulation, both in terms of reduction in insertion complications,5 decreased time to insertion,6 improved cost-effectiveness,17 and possibly even decreased risk of catheter-related sepsis.13 This has resulted in the formulation of NICE guidelines recommending the use of US guidance in the insertion of CVCs. The NICE guidelines refer particularly to insertions in the internal jugular vein, but there are a number of papers that show benefit for insertions in other sites.12 18 Despite the evidence supporting these guidelines, there has been considerable debate among anaesthetists about the necessity of their implementation. In a recent survey of the practice of paediatric anaesthetists, only 39% routinely used US,19 whereas a more recent survey (again of paediatric anaesthetics) by Tovey and colleagues20 found only 26% always used US. A survey of N. American cardiovascular anaesthesiologists found only 15% always used US21 with the most common reason given for not using US being ‘no apparent need’. Other reasons advanced for the reluctance to take up US range from the relative paucity of studies involving anaesthetists to the lack of representation on the NICE committee of anaesthetic consultants.22 The argument that US machines are not available no longer seems to hold water after the publication of a survey by Harris and colleagues23 that showed 86% of departments had a US locating device.

Before our department adopted the routine use of US, we found we had a 10.5% complication rate, which is broadly in line with accepted figures for the landmark technique.24 In our study, the implementation of the guidelines by the anaesthetic department of a hospital performing a wide range of procedures in a population with major pathology resulted in a significant reduction in complications from 10.5% to 4.6% (P < 0.01). Comparing US use and the landmark technique after implementation of the guidelines, there was a 6.9% reduction in complications, representing a number needed to prevent one complication of 14.5. Similar significant reductions in the number of failures were also seen with US.

Interestingly, our results would suggest that US afforded more benefit to SpRs than to consultants. The complication rate for SpRs has decreased from 12.3% with the landmark technique to 1.1%, an ARR of 11.2% (95% CI 2.9–19.5%) whereas that of consultants has seen a non-significant decrease from 4% to 2.6% (95% CI –5.2% to 7.8%). This is consistent with the meta-analysis by Keenan,5 which found that US conferred the greatest benefit for inexperienced clinicians and in our case is probably because the underlying complication rate for consultant performed insertions using the landmark technique was much lower than for the SpRs.

Although the use of the US now stands at 86%, uptake was initially poor. This was related to the time taken for individual practitioners to be trained in and to become comfortable with its use. Despite the NICE guidelines, there is no national recommendation for training. The Royal College of Radiology recommends that practical training in vascular US should involve at least two US lists per week over a period of no less than 3 months and up to 6 months, with approximately four to six examinations performed by the trainee under supervision per session.25 This is obviously impractical for the general anaesthetist who simply wishes to perform vascular access procedures.

Our training consisted of individual consultants attending the SonoSiteTM 1 day training course and then disseminating their training to others. New SpRs are now required to watch five US-guided insertions and then be supervised in performing a further five. The establishment of an agreed training programme may be a significant stumbling block that slows uptake in some centres.

Ours was an observational study, not blinded, or randomized. Practice changed during the second part of the audit as clinicians became more confident with the use of the US. It is also possible that awareness of our audit may have influenced practice. This is a potential source of bias.

In summary, our study of the effects of implementation of NICE guidelines on the complication rates of CVC insertion for an anaesthetic department in a busy tertiary referral centre supports the routine use of US by anaesthetists.


    Acknowledgement
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Acknowledgement
 References
 
We would like to thank the theatre department of the Royal Marsden Hospital, Fulham, London, for their participation in this audit.


    References
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Acknowledgement
 References
 
1 National Institute for Clinical Excellence. Guidance on the use of ultrasound locating devices for placing central venous catheters. Technology Appraisal Guidance No. 49 (2002) 9. Available from http://www.nice.org.uk.

2 Hind D, Calvert N, McWilliams R, et al. Ultrasonic locating devices for central venous cannulation: meta-analysis. Br Med J (2003) 327:361–7.[Abstract/Free Full Text]

3 Abboud P, Kendall J. Ultrasound guidance for vascular access. Emerg Med Clin North Am (2004) 22:749–73.[CrossRef][Web of Science][Medline]

4 Randolph AG, Cook DJ, Gonzales CA, et al. Ultrasound guidance for placement of central venous catheters. A meta-analysis of the literature. Crit Care Med (1996) 24:2053–8.[CrossRef][Web of Science][Medline]

5 Keenan SP. Use of ultrasound to place central lines. J Crit Care (2002) 17:126–37.[CrossRef][Web of Science][Medline]

6 Slama M, Novara A, Safavian A, et al. Improvement of internal jugular vein cannulation using an ultrasound-guided technique. Intensive Care Med (1997) 23:916–9.[CrossRef][Web of Science][Medline]

7 Verghese S, McGill W, Patel RI, et al. Ultrasound-guided internal jugular venous cannulation in infants: a prospective comparison with the traditional palpation method. Anesthesiology (1999) 91:71–7.[CrossRef][Web of Science][Medline]

8 Leyvi G, Taylor D, Reith E, et al. Utility of ultrasound-guided central venous cannulation in pediatric surgical patients: a clinical series. Paediatr Anaesth (2005) 15:953–8.[CrossRef][Medline]

9 Chuan W, Wei W, Yu L. A randomized-controlled study of ultrasound prelocation vs anatomical landmark-guided cannulation of the internal jugular vein in infants and children. Paediatr Anaesth (2005) 15:733–8.[CrossRef][Medline]

10 Nadig C, Leidig M, Schmiedeke T, et al. The use of ultrasound for the placement of dialysis catheters. Nephrol Dial Transplant (1998) 13:978–81.[Abstract/Free Full Text]

11 Koroglu M, Demir M, Koroglu BK, et al. Percutaneous placement of central venous catheters: comparing the anatomical landmark method with the radiologically guided technique for central venous catheterization through the internal jugular vein in emergent hemodialysis patients. Acta Radiol (2006) 47:43–7.[CrossRef][Web of Science][Medline]

12 Gualtieri E, Deppe S, Sipperly ME, et al. Subclavian venous catheterization: greater success rate for less experienced operators using ultrasound guidance. Crit Care Med (1995) 23:692–7.[CrossRef][Web of Science][Medline]

13 Karakitsos D, Labropoulos N, De Groot E, et al. Real-time ultrasound-guided catheterization of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Crit Care (2006) 10:R162.[CrossRef][Medline]

14 Hrics P, Wilber S, Blanda MP, et al. Ultrasound-assisted internal jugular vein catheterization in the ED. Am J Emerg Med (1998) 16:401–3.[CrossRef][Web of Science][Medline]

15 Leung J, Duffy M, Finckh A. Real-time ultrasonographically-guided internal jugular vein catheterization in the emergency department increases success rates and reduces complications: a randomized, prospective study. Ann Emerg Med (2006) 48:540–7.[CrossRef][Web of Science][Medline]

16 McGregor M, Rashid A, Sable N, et al. Impact of NICE guidance on the provision of ultrasound machines for central venous catheterization. Br J Anaesth (2006) 97:117–8.[Free Full Text]

17 Calvert N, Hind D, McWilliams R, et al. Ultrasound for central venous cannulation: economic evaluation of cost-effectiveness. Anaesthesia (2004) 59:1116–20.[CrossRef][Web of Science][Medline]

18 Hilty WM, Hudson PA, Levitt MA, et al. Real-time ultrasound-guided femoral vein catheterization during cardio-pulmonary resuscitation. Ann Emerg Med (1997) 29:331–6.[CrossRef][Web of Science][Medline]

19 Bosman M, Kavanagh RJ. Two dimensional ultrasound guidance in central venous catheter placement; a postal survey of the practice and opinions of consultant pediatric anesthetists in the United Kingdom. Paediatr Anaesth (2006) 16:530–7.[CrossRef][Medline]

20 Tovey G, Stokes M. A survey of the use of 2D ultrasound guidance for insertion of central venous catheters by UK consultant paediatric anaesthetists. Eur J Anaesthesiol (2007) 24:71–5.[Web of Science][Medline]

21 Bailey PL, Glance LG, Eaton MP, et al. A survey of the use of ultrasound during central venous catheterization. Anesth Analg (2007) 104:491–7.[Abstract/Free Full Text]

22 White SM. Not NICE advice. Anaesthesia (2003) 58:295–6.[CrossRef][Web of Science][Medline]

23 Harris N, Hodzovic I, Latto P. A national survey of the use of ultrasound locating devices for placing central venous catheters. Anaesthesia (2007) 62:306–7.

24 Sznajder JI, Zveibil FR, Bitterman H, et al. Central vein catheterization. Failure and complication rates by three percutaneous approaches. Arch Intern Med (1986) 146:259–61.[Abstract/Free Full Text]

25 Board of the Faculty of Clinical Radiology of the Royal College of Radiologists. In: Ultrasound Training Recommendations for Medical and Surgical Specialities (2004) London: Royal College of Radiologists.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
M. Morita, H. Sasano, T. Azami, N. Sasano, Y. Fujita, S. Ito, T. Sugiura, and K. Sobue
A Novel Skin-Traction Method Is Effective for Real-Time Ultrasound-Guided Internal Jugular Vein Catheterization in Infants and Neonates Weighing Less Than 5 Kilograms
Anesth. Analg., September 1, 2009; 109(3): 754 - 759.
[Abstract] [Full Text] [PDF]


Home page
CA Cancer J ClinHome page
M. Gallieni, M. Pittiruti, and R. Biffi
Vascular Access in Oncology Patients
CA Cancer J Clin, November 1, 2008; 58(6): 323 - 346.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
A. D. Leonard, C. M. Allsager, J. L. Parker, A. Swami, and J. P. Thompson
Comparison of central venous and external jugular venous pressures during repair of proximal femoral fracture
Br. J. Anaesth., August 1, 2008; 101(2): 166 - 170.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
L. A. Colvin and A. M. Moller
Volume 100: clinical investigations: where next?
Br. J. Anaesth., April 1, 2008; 100(4): 433 - 435.
[Full Text] [PDF]

E-letters:

Read all E-letters

NICE guidelines for cental venous catheter placement, are some people resistant to change?
Arun Krishnamurthy, et al.
British Journal of Anaesthesia, 3 Dec 2007 [Full text]
Effect of the implementation of NICE guidelines for ultrasound guidance on the complication rates as
Basil Almahdi, et al.
British Journal of Anaesthesia, 3 Dec 2007 [Full text]
Use of ultrasound for Central venous line placement-A different perspective
Ravish jeeji
British Journal of Anaesthesia, 8 Dec 2007 [Full text]
Training and Availability of US
Balamurugan Ramalingam
British Journal of Anaesthesia, 11 Dec 2007 [Full text]
Unintended consequencies of NICE Guidelines
Andrew Higgs, et al.
British Journal of Anaesthesia, 12 Dec 2007 [Full text]

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
99/5/662    most recent
aem262v1
Right arrow E-Letters: Submit a response to the article
Right arrow E-letters: View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Wigmore, T. J.
Right arrow Articles by MacCallum, N. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wigmore, T. J.
Right arrow Articles by MacCallum, N. S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?