Skip Navigation


BJA Advance Access originally published online on October 30, 2006
British Journal of Anaesthesia 2007 98(1):89-92; doi:10.1093/bja/ael286
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
98/1/89    most recent
ael286v1
Right arrow E-Letters: Submit a response to the article
Right arrow E-letters: View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (1)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Dhanani, J.
Right arrow Articles by Lipman, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dhanani, J.
Right arrow Articles by Lipman, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Board of Management and Trustees of the British Journal of Anaesthesia 2006. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

The entrapped central venous catheter

J. Dhanani1,2, S. Senthuran1,2, R. Olivotto3, R. J. Boots1,2 and J. Lipman1,2,*

1 Department of Intensive Care Medicine, Royal Brisbane and Women's Hospital Brisbane, Australia
2 Anaesthesiology and Critical Care, The University of Queensland Brisbane, Australia
3 Department of Radiology, Royal Brisbane and Women's Hospital Brisbane, Australia

*Corresponding author: Department of Intensive Care Medicine, 3rd Floor Ned Hanlon Building, Royal Brisbane and Women's Hospital Butterfield Street, Herston 4029, Brisbane, Australia. E-mail: j.lipman{at}uq.edu.au

Accepted for publication September 14, 2006.


    Abstract
 Top
 Abstract
 Introduction
 Case report
 Discussion
 Conclusion
 References
 
The central venous catheter (CVC) is associated with numerous complications more so during the process of insertion. We report for the first time how an indwelling catheter was entrapped by a replacement catheter on the same side, after being speared by the introducer needle and guidewire. The diagnosis was made when there was difficulty in removing the old catheter. Subsequently, interventional radiology services were used to define the problem and help in removal of the entrapped catheter. The mechanism of entrapment and the actual procedure used for removal of the catheter is described. The dangers of insertion of a CVC on the same side as a pre-existing one are highlighted.

Keywords: complications, catheter misplacement; equipment, cannulae intravascular


    Introduction
 Top
 Abstract
 Introduction
 Case report
 Discussion
 Conclusion
 References
 
The use of central venous catheters (CVC) is common in the setting of the intensive care unit for monitoring of central venous pressures, fluid administration and drug infusions. In the United States, 5 million CVCs are reported to be inserted every year.1 In our unit by current estimates, 1300 catheters are inserted per year. Complications of this procedure are well documented in the available literature25 and can arise during the insertion, maintenance or removal of the CVC. Mechanical complications such as breakage and subsequent embolization of distal fragments have been described.25

We describe the first ‘entrapped catheter’ and its successful removal.


    Case report
 Top
 Abstract
 Introduction
 Case report
 Discussion
 Conclusion
 References
 
A 48 yr female was admitted with polytrauma after a motor vehicle accident. She had extensive injuries including bilateral haemothoraces. She developed post-admission complications of ventilator-associated pneumonia and multi-organ dysfunction with acute renal failure needing continuous renal replacement therapy.

On day 7 of admission a 20 cm long, 7.5 Fr triple lumen CVC (Cook Spectrum) was placed in right subclavian vein using the infraclavicular approach and a Seldinger technique. Anatomical landmarks were used to guide placement. The catheter was inserted to the 15 cm mark at the skin insertion site with the position checked by a chest radiograph.

Seven days later, replacement of the CVC was planned as a result of an unsourced inflammatory response and clinically suspected catheter-related sepsis.

Using the Seldinger technique via a supraclavicular approach to the right subclavian vein a CVC of the same type was inserted. However, it was noticed that although the line was inserted with a single pass, some resistance was encountered while advancing the catheter over the guidewire. Blood was aspirated from all three lumens, and a chest roentgenogram (CXR) confirmed an adequate position.

Some time later, the nurse caring for the patient reported resistance while attempting to remove the original (first) catheter. Despite gentle traction and clavicular manoeuvring, the medical staff also could not remove the catheter and interventional radiology was asked to assist in the removal of the trapped catheter.

Initial fluoroscopy demonstrated the two catheters in close approximation. No kinking or knotting was evident. Aspiration of each lumen of the triple lumen central line due for removal was attempted but was unsuccessful. A Terumo stiff guide wire (Terumo; Watertown, MA) was passed down the lumen of this CVC. But when the CVC was pulled on, the newer CVC appeared to move along with it at the point where the two intersected and appeared to pinch the new CVC. The wire was removed and contrast instilled via each of the lumens of the original CVC. This demonstrated some contrast leakage at the point of intersection and back along the subcutaneous tract. Contrast also flowed from the end of the CVC confirming its intravascular location. Contrast was then injected down the new CVC to confirm it was intact.

As both CVCs were the same size it was noticed the original CVC entrapped the new CVC such as a vice, this being demonstrated when traction was applied (seen in Fig. 1A). Rotating the original catheter allowed release of the entrapment and easy withdrawal of the original CVC, as demonstrated in Figure 1B.


Figure 1
View larger version (9K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Fig 1 (A) Original CVL damaged during placement of the second CVL, entrapping the new line. (B) Original CVL rotated allowing release of the second CVL. The original damaged CVL could then be removed.

 
Post-removal, inspection of the line confirmed entrapment (Fig. 2). It was seen that the catheter wall had a slit-like opening at the site where the new CVC would have gone through it as per the radiological images.


Figure 2
View larger version (37K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Fig 2 (A and B) show the tear of the original central venous catheter.

 
The new CVC was left in situ. No documented complications arose from the procedure.


    Discussion
 Top
 Abstract
 Introduction
 Case report
 Discussion
 Conclusion
 References
 
Since the beginning of its use, the CVC has been associated with numerous complications of varied severity broadly classified as mechanical, infective and thrombotic.

Mechanical complications and the management thereof have been studied and documented.26 Shear/fracture of the CVC is also a recognized complication with incidence of 2.5% over a 5 yr period at one centre.7

In our case, we surmise the cutting edge of the introducer needle to have caused the initial fracture and the subsequent insertion of the guide wire directing the new CVC into the fracture. The second CVC had speared the original catheter, thus preventing its removal (Figs 1 and 2). A catastrophic complication in the form of complete fracture and embolization of the distal fragment of CVC could have resulted if there had been excessive traction on the original CVC.

The possible causes of the difficulty in removing the original CVC could have been a ‘pinch off’, fibrin sheath or entanglement/knotting.

Direct imaging by interventional radiology allowed the complication to be accurately diagnosed with successful line removal (see Fig. 1).

Various methods of dealing with fractured CVC have been explored. For incomplete fractures: (i) slow gentle traction8 and (ii) cutaneous cut-down followed by distal venotomy for incompletely fractured catheters.4 For complete fractures: (i) radiological loops, snares, coils—the use of more sophisticated devices such as grasping forceps, baskets or balloons rarely overcome the failure of a loop snare9 and (ii) surgical exploration.

The role of radiology in the diagnosis and management of complications related to central venous access is well described.10 Diagnosis of catheter fragmentation is usually made on the basis of a chest radiograph in two views. Therapy consists of interventional radiological removal of the CVC fragment.

At one centre 95% successful retrieval of embolized fragment by interventional radiological procedures has been reported.9

Hazards and caution during multiple cannulation of the same vein have been described.11 Mahadeva and colleagues3 reported shearing and partial fracture of the old CVC making removal difficult after repeated attempts at a new CVC insertion. A venotomy was required.

Our case and previous reports caution the insertion of CVC on the same side as an existing CVC. Once shearing of the catheter is suspected, the method of removal should be determined by the institutional resources. Resistance during CVC insertion from the introducer needle, guide wire or the catheter itself, should caution to cease further attempts at same vessel before the existing cannula is removed unless imaging is available to guide the insertion.

If entrapment is suspected then accurate diagnosis and appropriate management is essential in preventing catastrophic complications such as fragment embolization. Hence, a low threshold for referral to interventional radiology should be maintained. If necessary, referrals to appropriate centres should be made.

Figure 3 shows the algorithmic approach towards the diagnosis and management of an entrapped CVC.


Figure 3
View larger version (16K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Fig 3 Diagnosis and management of entrapped central venous catheter.

 

    Conclusion
 Top
 Abstract
 Introduction
 Case report
 Discussion
 Conclusion
 References
 
In summary, we describe an unusual case of entrapped catheter by a pre-existing catheter and a safe and effective means to remove it and also an algorithm for the diagnosis and management of the entrapped CVC (Fig. 3). Careful observation and immediate attention to the problem can prevent more serious sequelae such as embolization of the fragmented catheter tip. We recommend caution during the insertion of a CVC on the same side as a pre-existing CVC. When resistance is encountered at any stage of CVC insertion the procedure should either be abandoned or re-attempted with imaging assistance. Clinicians need to be aware of this rare complication and its correction by interventional radiology.9 We propose an algorithm for the diagnosis and management of the entrapped CVC (Fig. 3).


    References
 Top
 Abstract
 Introduction
 Case report
 Discussion
 Conclusion
 References
 
1 McGee DC and Gould MK. Preventing complications of central venous catheterization. N Eng J Med 2003; 348:1123–33[Free Full Text]

2 Arenas-Marquez H, Anaya-Prado R, Barrera-Zepeda LM, Gonzalez-Ojeda A. Complications of central venous catheters. Curr Opin Clin Nutr Metab Care 2001; 4:207–10[CrossRef][Web of Science][Medline]

3 Mahadeva S, Cohen A, Bellamy M. The stuck central venous catheter: beware of potential hazards. Br J Anaesth 2002; 89:650–2[Abstract/Free Full Text]

4 Philip KN, Ault MJ, Fishbein MC. The stuck catheter: a case report. Mt Sinai J Med 1997; 64:350–52[Medline]

5 Ramsden WH, Cohen AT, Blanshard KS. Case report: central venous catheter fracture due to compression between the clavicle and first rib. Clin Radiol 1995; 50:59–60[CrossRef][Web of Science][Medline]

6 Andris DA. Vascular access devices: expect the unexpected. Nutr Clin Pract 2000; 15:201–2

7 Trotter C and Carey BE. Tearing and embolization of percutaneous central venous catheters. Neonatal Netw 1998; 17:67–71[Medline]

8 Gladman G, Sinha S, Sims DG, Chiswick ML. Staphylococcus epidermidis and retention of neonatal percutaneous central venous catheters. Arch Dis Child 1990; 65:234–5[Abstract/Free Full Text]

9 Bessoud B, de Baere T, Kuoch V, et al. Experience at a single institution with endovascular treatment of mechanical complications caused by implanted central venous access devices in pediatric and adult patients. Am J Roentgenol 2003; 180:527–32[Abstract/Free Full Text]

10 Knutstad K, Hager B, Hauser M. Radiologic diagnosis and management of complications related to central venous access. Acta Radiol 2003; 44:508–16[CrossRef][Web of Science][Medline]

11 Withington PS and Carter JA. Hazards in multiple cannulation of a single vein. Anaesthesia 1985; 40:700[Web of Science][Medline]


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
V. Paul, J. Dhanani, S. Senthuran, R. Olivotto, R. J. Boots, and J. Lipman
Entrapped central venous catheter
Br. J. Anaesth., May 1, 2007; 98(5): 695 - 695.
[Full Text] [PDF]

E-letters:

Read all E-letters

Won the battle but lost the war ?
Dr V Paul, et al.
British Journal of Anaesthesia, 4 Jan 2007 [Full text]
Reply to the questions
Jayesh Dhanani, et al.
British Journal of Anaesthesia, 19 Jan 2007 [Full text]
Entrapped central venous catheter
prakash k. dubey
British Journal of Anaesthesia, 16 Feb 2007 [Full text]

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
98/1/89    most recent
ael286v1
Right arrow E-Letters: Submit a response to the article
Right arrow E-letters: View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (1)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Dhanani, J.
Right arrow Articles by Lipman, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dhanani, J.
Right arrow Articles by Lipman, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?