Skip Navigation


BJA Advance Access originally published online on February 7, 2006
British Journal of Anaesthesia 2006 96(4):455-463; doi:10.1093/bja/ael019
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
96/4/455    most recent
ael019v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (5)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by von Roten, I.
Right arrow Articles by Spahn, D. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by von Roten, I.
Right arrow Articles by Spahn, D. R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Board of Management and Trustees of the British Journal of Anaesthesia 2006. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Molar substitution and C2/C6 ratio of hydroxyethyl starch: influence on blood coagulation{dagger}

I. von Roten1, C. Madjdpour1, P. Frascarolo1, M.-A. Burmeister2, A. Fisch3, S. Schramm1, T. Bombeli4 and D. R. Spahn1,*

1Department of Anaesthesiology, University Hospital Lausanne Lausanne, Switzerland
2Department of Anaesthesiology, B. Braun Melsungen AG Melsungen, Germany
3Pharmaceutical Development, B. Braun Medical SA Crissier, Switzerland
4Coagulation Laboratory, Division of Haematology, University Hospital of Zürich Zurich, Switzerland

*Corresponding author. E-mail: donat.spahn{at}chuv.ch

Accepted for publication December 16, 2005.


    Abstract
 Top
 Abstract
 Introduction
 Materials and methods
 Results
 Discussion
 References
 
Background. Development of hydroxyethyl starches (HES) with a low impact on blood coagulation but a long intravascular persistence is of clinical interest. A previous in vitro study showed that low substituted high molecular weight HES does not compromise blood coagulation more than medium molecular weight HES. In the present study we assessed the individual effects on blood coagulation of molar substitution and C2/C6 ratio of a high molecular weight HES.

Methods. Blood was obtained from 30 healthy patients undergoing elective surgery and mixed with six high molecular weight (700 kDa) HES solutions differing in their molar substitution (0.42 and 0.51) and C2/C6 ratio (2.7, 7 and 14) to achieve 20, 40 and 60% dilution. Blood coagulation was assessed by Thrombelastograph® analysis (TEG) and plasma coagulation tests.Data were compared using a three-way analysis of variance model with repeated measures on the three factors.

Results. Higher molar substitution compromised blood coagulation most (for all TEG parameters, P<0.05). The lowest C2/C6 ratio was associated with the lowest effect on blood coagulation; r (P<0.001), angle {alpha} (P=0.003) and coagulation index (P<0.001). No effect on k and maximum amplitude was observed (P for both >0.50). The higher molar substitution was associated with a lesser increase in PT (P=0.007) and a greater decrease in factor VIII (P=0.010). PTT, functional and antigenic von Willebrand factors were not significantly influenced by molar substitution (P for all >0.20). No significant differences between solutions with the same molar substitution but different C2/C6 ratios were found in plasma coagulation parameters (P for all >0.05).

Conclusions. TEG analysis indicates that high molecular HES with a molar substitution of 0.42 and a C2/C6 ratio of 2.7 has the lowest effect on in vitro human blood coagulation.

Keywords: blood, coagulation; colloid; starch, hydroxyethyl


    Introduction
 Top
 Abstract
 Introduction
 Materials and methods
 Results
 Discussion
 References
 
Hydroxyethyl starches (HES) are widely used plasma substitutes.14 The clinical use of HES is limited by its impact on blood coagulation associated with a reduction of circulating levels of factor VIII and von Willebrand Factor (vWF) in a greater proportion than expected by plasma dilution.57 Direct inhibition of platelet function through binding of HES to the platelet surface may also contribute to the blood coagulation compromising effects of HES.4 8

HES is a modified branched natural polymer of amylopectin. Besides its molecular weight, HES is characterized by its molar substitution, which expresses the average number of hydroxethyl groups per unit of glucose, and by the C2/C6 ratio, which describes more precisely the substitution pattern: indeed, the hydroxyethyl units can be introduced at positions 2, 3 and 6 of the glucose unit but most frequently at positions C2 and C6, so that the C2/C6 ratio is commonly indicated.2 4

There was a generally held view that low molecular weight HES affects blood coagulation to a lesser extent than high molecular HES. Indeed, studies comparing high vs medium and low molecular weight HES confirmed this advantage of medium and low molecular weight HES.5 9 However, in these studies, a reduction in molecular weight has always been associated with a reduction in molar substitution.

A preliminary in vitro study10 showed that two high molecular HES solutions with a molar substitution of 0.4, HES 500/0.4 and HES 800/0.4 (molecular weight/molar substitution), had a slightly reduced effect on blood coagulation compared with HES 200/0.5. In addition, an in vivo study showed that, at low substitution, high molecular weight HES did not compromise blood coagulation to a greater extent than low molecular weight HES.11 We tested the hypothesis that molar substitution might be a key factor in determining the effect of a HES solution on blood coagulation.

The present study assesses systematically the individual effects of molar substitution and C2/C6 ratio and the possibility of an interaction between these two parameters on the reduced coagulation produced by high molecular weight HES.


    Materials and methods
 Top
 Abstract
 Introduction
 Materials and methods
 Results
 Discussion
 References
 
This study of 30 patients was approved by our local ethics committee and each patient gave written informed consent. Patients between 18 and 80 yr of age undergoing various surgical procedures were enrolled. Exclusion criteria were emergency surgery, a history of preoperative coagulation disorders, anticoagulation, treatment with acetylsalicylic acid or nonsteroidal anti-inflammatory drugs within 5 days before surgery, history of renal dysfunction or increased serum creatinine levels (>120 µmol litre–1), history of liver dysfunction or increased plasma levels of aspartate aminotransferase (>50 u litre–1) or alanine aminotransferase (> 50 u litre–1), treatment with HES solutions within 30 days before surgery and ASA III or IV classification as judged by the responsible anaesthesiologist. A standard prophylaxis of 3000 u of s.c. low molecular weight heparin the day before surgery was allowed.

Eighty millilitres of blood was removed from an antecubital vein by direct venipuncture using a 19 gauge butterfly connected to 10 ml monovettes containing 3.13% trisodium citrate (S-Monovette 10 ml 9 NC, Sarstedt, Nümbrecht, Germany). The first 10 ml of blood was discarded to avoid activation of blood coagulation.

The blood from eight citrated monovettes was added into one polystyrene tube to produce one homogenous sample, and the whole blood was then incubated at 37°C for 1 h.12 The blood was then diluted. All 18 different possible dilutions (six different HES solutions at three dilutions; see Fig. 1) were initially made with one blood sample using blinded HES solutions labelled A, B, C, D, E and F. The diluted samples were again maintained for 1 h at 37°C in an incubator.12


Figure 1
View larger version (8K):
[in this window]
[in a new window]
 
Fig 1 Design of the trial: the blood was diluted at 20, 40 and 60% with each of the six blinded solutions (A, B, C, D, E and F) in polystyrene tubes yielding 5 ml of blood–HES mixtures.

 
TEG analysis was performed using two computerized Thrombelastograph® coagulation analysers 5000 (TEG, Haemoscope Corporation, Niles, IL, USA). Four samples were analysed at a time and the sequences of analysis and the TEG channels were randomly chosen for each patient using the randomly permuted blocks method. One millilitre of diluted blood was added to a tube containing 1% kaolin. The tube was mixed and an aliquot of 340 µl kaolin activated blood was then placed into the TEG cup containing 20 µl of 2 M CaCl2. TEG analysis started immediately. Haemoglobin concentration was determined with a blood gas analyser (Bayer Diagnostic Ltd, model 865, Bayer, Zürich, Switzerland) using arterial blood samplers containing lyophilized lithium heparin (Marquest Quik A.B.G., Englewood, CO, USA).

For prothrombin time (PT), activated partial thromboplastin time (aPTT), factor VIII and vWF measurements, samples were centrifuged at 3000 rpm for 15 min at 4°C (Rotanta/RP, Hettich, Bäch, Switzerland). PT and aPTT were determined on an automated coagulation analyser (BCS, Dade Behring, Marburg, Germany) using a PT reagent containing recombinant tissue factor (Innovin®, Dade Behring) and an aPTT reagent containing ellagic acid (Actin FS®, Dade Behring), respectively. Factor VIII was assessed functionally using factor VIII-deficient plasma (Helena Haemostasis Systems Ltd, Sunderland, Tyne and Wear, UK). Functional activity of vWF was determined in a commercial ristocetin-cofactor assay (vWF RCA, Dade Behring) on an automated coagulation analyser (BCS, Dade Behring). Briefly, vWF activity was assessed by the ability to agglutinate fixed human platelets in the presence of ristocetin. Agglutination was turbidimetrically measured by the coagulation analyser. Antigenic vWF levels were assayed by a commercial ELISA kit (Asserachrom vWF antigenic, Roche Diagnostics, Rotkreuz, Switzerland) according to the manufacturer's instructions.

HES syntheses
Thin-boiling waxy maize starch was suspended in water, activated by means of sodium hydroxide, and allowed to react with ethylene oxide for 2 h at 40°C. The amounts of waxy maize starch and ethylene oxide were chosen to yield HES with molar substitutions of 0.42 and 0.51. HES C2/C6 ratios of 2.7, 7 and 14 were obtained by changing the quantities of sodium hydroxide during hydroxyethylation. All raw HES species were hydrolysed by hydrochloric acid to molecular weights of 700 kDa, treated with activated carbon, purified by ultra-filtration and diluted to a final concentration of 6% (w/v) in isotonic saline, filled in glass bottles of 500 ml each, and heat-sterilized at 121°C for 20 min. HES synthesis was performed in the laboratories of B. Braun Medical SA, Crissier, Switzerland.

HES characterization
Mean molecular weight (Mw) of HES was determined by GPC-MALLS (Wyatt Technology, Woldert, Germany) at a flow rate of 1 ml min–1 in a 70 mM phosphate buffer pH 7.0 using serial GPC columns HEMA Bio 40, 100 and 1000 (PSS, Mainz, Germany). Mw was calculated using ASTRA Software (Wyatt Technology, Woldert, Germany).

Molar substitution was determined by gas chromatography after transforming hydroxyethyl groups into ethyl iodine by hydriodic acid in the presence of adipic acid using a gas chromatograph (Perkin Elmer Autosystem; Boston, MA, USA). C2/C6 ratio was determined after hydrolysis of HES by sulphuric acid and gas chromatographic separation of the silylated hydroxyethylated glucose derivatives using a gas chromatograph (Carlo Erba Mega 5300; Milan, Italy).

Statistical analysis
Sample size has been determined by a power analysis based on a previous in vitro study.10 To obtain a power of 80% with an estimated difference between groups of 10% and a SD of 15% a total sample size of 30 patients has been determined with a type I error of 0.05.

All data were calculated as changes vs baseline and reported as mean (SD). A three-way analysis of variance model with repeated measures on three ways was constructed using the JMP 5.1 statistical package (SAS Institute, Inc., Cary, NC) for assessing the effect of molar substitution, C2/C6 ratio and dilution, respectively, and all possible interaction between these factors. Thus, the variability was partitioned into the following components: molar substitution, C2/C6 ratio, interaction between molar substitution and C2/C6 ratio, dilution, interaction between dilution and C2/C6 ratio, interaction between dilution and molar substitution, and interaction between all three factors.


    Results
 Top
 Abstract
 Introduction
 Materials and methods
 Results
 Discussion
 References
 
Plasma coagulation and TEG parameters were normal at baseline (Table 1).


View this table:
[in this window]
[in a new window]
 
Table 1 Baseline values. Data are mean (SD). The following parameters were measured: TEG: r-time, k-time, angle {alpha}, MA, shear elastic modulus (G) and CI; plasma coagulation: PT, aPTT, functional vWF and antigenic vWF (AG vWF) and factor VIII (F VIII)

 
Dilution effect
Haemoglobin decreased from 12.2 (1.3) to 9.8 (1.2) g dl–1 (20% dilution), 7.6 (1.0) g dl–1 (40% dilution) and 5.2 (0.8) g dl–1 (60% dilution) because of in vitro haemodilution (P<0.001). No difference was found between the different HES solutions investigated. Dilution alone had a significant effect on all TEG parameters and on all plasma coagulation parameters (P<0.001 for all parameters): the more the blood was diluted, the more the coagulation was compromised (see Figs 25).


Figure 2
View larger version (18K):
[in this window]
[in a new window]
 
Fig 2 Effects of molar substitution (MS) on TEG analysis. Blood samples were diluted with HES solutions with a MS 0.42 or 0.51 at dilutions of 20% (Dil_20), 40% (Dil_40) and 60% (Dil_60). The following TEG parameters were measured: r-time (A), k-time (B), angle {alpha} (C), MA (D), shear elastic modulus (G) (E) and CI (F). Mean (SD) changes vs baseline are depicted (n=30).

 

Figure 5
View larger version (19K):
[in this window]
[in a new window]
 
Fig 5 Effects of C2/C6 ratio on plasma coagulation. Blood samples were diluted with HES solutions with C2/C6 ratio of 2.7, 7 or 14 at dilutions of 20% (Dil_20), 40% (Dil_40) and 60% (Dil_60). The following plasma coagulation parameters were measured: PT (A), factor VIII (B), aPTT (C), functional vWF (D) and antigenic vWF (E). Mean (SD) changes vs baseline are depicted (n=30).

 
Molar substitution effect
TEG
The higher molar substitution of 0.51 resulted in a greater compromise in blood coagulation for all TEG parameters: r-time (P<0.001) and k-time (P=0.031) were prolonged more when diluted using a HES solution with a molar substitution of 0.51 than when diluted using a HES solution with a molar substitution of 0.42 (Fig. 2A and B). Angle {alpha} (P=0.008), maximal amplitude (MA) (P=0.013), G (P=0.003) and coagulation index (CI) (P=0.007) showed a stronger decrease when diluted with a HES solution with a molar substitution of 0.51 than when diluted with a HES solution with a molar substitution of 0.42 (Fig. 2CF).

Plasma coagulation
PT (P=0.007) increase was lower and factor VIII (P=0.010) decrease was greater when diluted using a HES solution with a molar substitution of 0.51 than when diluted using a HES solution with a molar substitution of 0.42 (Fig. 3A and B) while aPTT (P=0.213), functional and antigenic vWFs (P=0.782 and 0.296, respectively) showed no significant differences when diluted using HES solutions with a molar substitution of 0.51 or 0.42 (Fig. 3CE).


Figure 3
View larger version (16K):
[in this window]
[in a new window]
 
Fig 3 Effects of molar substitution (MS) on plasma coagulation. Blood samples were diluted with HES solutions with a MS 0.42 or 0.51 at dilutions of 20% (Dil_20), 40% (Dil_40) and 60% (Dil_60). The following plasma coagulation parameters were measured: PT (A), factor VIII (B), aPTT (C), functional vWF (D) and antigenic vWF (E). Mean (SD) changes vs baseline are depicted (n=30).

 
C2/C6 ratio effect
TEG
HES solutions with different C2/C6 ratios affected r-time (P<0.001), angle {alpha} (P=0.003) and CI (P<0.001) (Fig. 4AC), while there were no significant differences between these solutions for k-time (P=0.513), MA (P=0.699) and G (P=0.246) (Fig. 4DF).


Figure 4
View larger version (22K):
[in this window]
[in a new window]
 
Fig 4 Effects of C2/C6 ratio on TEG analysis. Blood samples were diluted with HES solutions with C2/C6 ratio of 2.7, 7 or 14 at dilutions of 20% (Dil_20), 40% (Dil_40) and 60% (Dil_60). The following TEG parameters were measured: r-time (A), angle {alpha} (B), CI (C), k-time (D), MA (E) and shear elastic modulus (G) (F). Mean (SD) changes vs baseline are depicted (n=30).

 
Plasma coagulation
No significant differences between solutions with different C2/C6 ratios was found concerning PT (P=0.061), factor VIII (P=0.099), aPTT (P=0.086), functional and antigenic vWFs (P=0.916 and 0.064, respectively) (Fig. 5).

Interactions
A significant interaction between molar substitution and C2/C6 ratio was found for r-time, angle {alpha} and CI (all P<0.001). At a molar substitution of 0.42, k-time was progressively prolonged and angle {alpha} and CI were progressively reduced with increasing C2/C6 ratios (Fig. 6). In contrast, at a molar substitution of 0.51, a C2/C6 ratio of 7 resulted in a maximum compromise of blood coagulation (Fig. 6). No significant interaction was found for k-time (P=0.786), MA (P=0.696), G (P=0.489), PT (P=0.343), factor VIII (P=0.874), aPTT (P=0.237), functional and antigenic vWFs (P=0.865 and 0.821, respectively).


Figure 6
View larger version (17K):
[in this window]
[in a new window]
 
Fig 6 TEG parameters for which a significant interaction between molar substitution (MS) and C2/C6 ratio was found for HES solutions with a MS of 0.42 (left) or a MS of 0.51 (right) at dilutions of 20% (Dil_20), 40% (Dil_40) and 60% (Dil_60): r-time (A and B), angle {alpha} (C and D) and CI (E and F). Mean (SD) changes vs baseline are depicted (n=30).

 

    Discussion
 Top
 Abstract
 Introduction
 Materials and methods
 Results
 Discussion
 References
 
This study indicates that HES 700/0.42/2.7 (molecular weight/molar substitution/C2/C6 ratio) has a less pronounced effect on in vitro human blood coagulation than HES solutions of the same molecular weight with a higher degree of molar substitution and a higher C2/C6 ratio.

Molecular weight has been considered for a long time as a key factor in determining the compromising effects of HES on blood coagulation.1 2 However, in recent years the development of HES was always characterized by a concomitant reduction in molecular weight and molar substitution whereas the isolated effect of the molecular weight has not been systematically examined. Only recently Madjdpour and colleagues11 tested HES molecules with different molecular weights but identical molar substitution. They found that, at a low molar substitution (0.42), high molecular weight HES does not compromise blood coagulation to a greater extent than low molecular weight HES with the same molar substitution.

Treib and colleagues13 studied the effect of molar substitution on blood coagulation. They showed that a HES 200/0.62 solution affected coagulation of human blood more than HES 200/0.5. Unfortunately, the C2/C6 ratio of the solutions used was not indicated. Furthermore, only plasma coagulation but not TEG analyses have been performed with the latter providing a complementary view on the process of blood coagulation by testing the kinetics of the whole coagulation process.14

An in vitro study investigated the effect of HES 70/0.5/3.2, HES 130/0.4/11.2 and HES 200/0.5/4.6 solutions on blood coagulation and found a reduced effect on blood coagulation of HES 130/0.4/11.2.15 The authors postulated that the smaller molar substitution might be responsible for this beneficial effect. However, in this study, molecular weight, molar substitution and C2/C6 ratio varied considerably. Thus, it is difficult to allocate precisely an effect to one parameter. Interestingly, Niemi and Kuitunen16 recently found in an in vitro study that HES 120/0.7 compromised blood coagulation less than HES 130/0.4. Unfortunately, the C2/C6 ratio was not described.

This illustrates the need for systematic studies, which may only be possible in vitro, elucidating the complex interplay between molecular weight, molar substitution and the C2/C6 ratio on the effect of HES on blood coagulation. In such a study, we have now found that in high molecular HES a molar substitution of 0.42 and a C2/C6 ratio of 2.7 results in slightly reduced in vitro blood coagulation compromising effects. The observed differences are obviously small but the study design allowed paired comparisons and had thus the power to detect even minor differences. Extrapolating this finding to clinical practice is fraught with difficulties and certainly requires confirmatory in vivo studies. Also the effect of the relatively low C2/C6 ratio on pharmacokinetics needs to be equally assessed in vivo.

Prophylactic s.c. low-molecular weight heparin does not modify TEG parameters.17 This is in keeping with the finding that baseline TEG parameters were in the normal range in this study (Table 1), as they were in several previous studies.12 18 19

The ideal properties of a HES solution may differ between the intraoperative and the postoperative period. Intraoperatively, a minimal effect on blood coagulation is certainly important. A longer intravascular retention time may be desirable after operation, whereas a certain blood coagulation compromising effect may not necessarily be deleterious. In fact, McCrath and colleagues20 have recently shown that patients already with a minimal hypercoagulability at the end of surgery had a higher incidence of major thromboembolic complications such as ischaemic strokes, myocardial infarctions, deep venous thrombosis and venous thromboembolism after operation despite standard thromboembolic prophylaxis.

In conclusion, a molar substitution of 0.42 and a C2/C6 ratio of 2.7 were found to be associated with the least compromise on blood coagulation in high molecular (700 kDa) HES. Further studies are necessary to assess whether such a HES also compromises in vivo blood coagulation minimally and whether its intravascular retention is indeed higher than a low molecular, low substituted HES such as a HES 130/0.42.


    Acknowledgments
 
We are grateful to Alvine Bissery from the Clinical Epidemiology Centre, Institute of Social and Preventive Medicine, University of Lausanne, for her assistance regarding the statistical analysis. We acknowledge financial support from departmental funds and B. Braun Melsungen AG, D-34209 Melsungen, Germany.


    Footnotes
 
{dagger}Declaration of interest. This study was funded by a grants from B. Braun Melsungen AG and the Department of Anaesthesiology of the University Hospital Lausanne. Marc-Alexander Burmeister and Andreas Fisch are employees of B. Braun AG (Melsungen and Crissier) and Donat R. Spahn is doing paid consulting for B. Braun Medical AG, Switzerland. The Department of Anaesthesiology of the University Hospital Lausanne has done other research projects in collaboration with B. Braun Melsungen AG and has thereby received other funding in the past. The Department of Anesthesiology of the University Hospital Lausanne has also received educational funds from competitor companies. Back


    References
 Top
 Abstract
 Introduction
 Materials and methods
 Results
 Discussion
 References
 
1 American Thoracic Society. Evidence-based colloid use in the critically ill: American Thoracic Society Consensus Statement. Am J Respir Crit Care Med 2004; 170:1247–59[Free Full Text]

2 Treib J, Baron JF, Grauer MT, Strauss RG. An international view of hydroxyethyl starches. Intensive Care Med 1999; 25:258–68[CrossRef][ISI][Medline]

3 Boldt J. New light on intravascular volume replacement regimens: what did we learn from the past three years? Anesth Analg 2003; 97:1595–604[Abstract/Free Full Text]

4 Kozek-Langenecker SA. Effects of hydroxyethyl starch solutions on hemostasis. Anesthesiology 2005; 103:654–60[ISI][Medline]

5 Jamnicki M, Bombeli T, Seifert B, et al. Low- and medium-molecular-weight hydroxyethyl starches: comparison of their effect on blood coagulation. Anesthesiology 2000; 93:1231–7[CrossRef][ISI][Medline]

6 Langeron O, Doelberg M, Ang ET, Bonnet F, Capdevila X, Coriat P. Voluven, a lower substituted novel hydroxyethyl starch (HES 130/0.4), causes fewer effects on coagulation in major orthopedic surgery than HES 200/0.5. Anesth Analg 2001; 92:855–62[Abstract/Free Full Text]

7 de Jonge E and Levi M. Effects of different plasma substitutes on blood coagulation: a comparative review. Crit Care Med 2001; 29:1261–7[CrossRef][ISI][Medline]

8 Deusch E, Gamsjager T, Kress HG, Kozek-Langenecker SA. Binding of hydroxyethyl starch molecules to the platelet surface. Anesth Analg 2003; 97:680–3[Abstract/Free Full Text]

9 Entholzner EK, Mielke LL, Calatzis AN, Feyh J, Hipp R, Hargasser SR. Coagulation effects of a recently developed hydroxyethyl starch (HES 130/0.4) compared to hydroxyethyl starches with higher molecular weight. Acta Anaesthesiol Scand 2000; 44:1116–21[CrossRef][ISI][Medline]

10 Julier K, Dettori N, Madjdpour C, Frascarolo PH, Spahn DR. Molecular weight does not determine the effect of hydroxyethyl starch on in vitro blood coagulation. Anesthesiology 2004; 101:A723

11 Madjdpour C, Dettori N, Frascarolo P, et al. Molecular weight of hydroxyethyl starch: is there an effect on blood coagulation and pharmacokinetics? Br J Anaesth 2005; 94:569–76[Abstract/Free Full Text]

12 Camenzind V, Bombeli T, Seifert B, et al. Citrate storage affects Thrombelastograph analysis. Anesthesiology 2000; 92:1242–9[CrossRef][ISI][Medline]

13 Treib J, Haass A, Pindur G, Grauer MT, Wenzel E, Schimrigk K. All medium starches are not the same: influence of the degree of hydroxyethyl substitution of hydroxyethyl starch on plasma volume, hemorrheologic conditions, and coagulation. Transfusion 1996; 36:450–5[CrossRef][ISI][Medline]

14 Pivalizza EG and Abramson DC. Thromboelastography: another point of view. Anesth Analg 2001; 93:517–18[Free Full Text]

15 Konrad CJ, Markl TJ, Schuepfer GK, Schmeck J, Gerber HR. In vitro effects of different medium molecular hydroxyethyl starch solutions and lactated Ringer's solution on coagulation using SONOCLOT. Anesth Analg 2000; 90:274–9[Abstract/Free Full Text]

16 Niemi TT and Kuitunen AH. Artificial colloids impair haemostasis. An in vitro study using thromboelastometry coagulation analysis. Acta Anaesthesiol Scand 2005; 49:373–8[Medline]

17 Leonard SA, Lydon A, Walsh M, Fleming C, Boylan J, Shorten GD. Does prior administration of enoxaparin influence the effects of levobupivacaine on blood clotting? Assessment using the Thrombelastograph. Br J Anaesth 2001; 86:808–13[Abstract/Free Full Text]

18 Egli GA, Zollinger A, Seifert B, Popovic D, Pasch T, Spahn DR. Effect of progressive haemodilution with hydroxyethyl starch, gelatin and albumin on blood coagulation. Br J Anaesth 1997; 78:684–9[Abstract/Free Full Text]

19 Jamnicki M, Zollinger A, Seifert B, Popovic D, Pasch T, Spahn DR. Compromised blood coagulation: an in vitro comparison of hydroxyethyl starch 130/0.4 and hydroxyethyl starch 200/0.5 using thrombelastography. Anesth Analg 1998; 87:989–93[Abstract/Free Full Text]

20 McCrath DJ, Cerboni E, Frumento RJ, Hirsh AL, Bennett-Guerrero E. Thromboelastography maximum amplitude predicts postoperative thrombotic complications including myocardial infarction. Anesth Analg 2005; 100:1576–83[Abstract/Free Full Text]


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
D. Viuff, B. Lauritzen, A.E. Pusateri, S. Andersen, R. Rojkjaer, and P.I. Johansson
Effect of haemodilution, acidosis, and hypothermia on the activity of recombinant factor VIIa (NovoSeven(R))
Br. J. Anaesth., June 18, 2008; (2008) aen175v1.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
T. Hitosugi, T. Saito, S. Suzuki, I. Kubota, E. Shoda, T. Shimizu, and Y. Oi
Hydroxyethyl Starch: The Effect of Molecular Weight and Degree of Substitution on Intravascular Retention In Vivo
Anesth. Analg., September 1, 2007; 105(3): 724 - 728.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
A. Butwick and B. Carvalho
The effect of colloid and crystalloid preloading on thromboelastography prior to Cesarean delivery: [L'effet d'une precharge avec un colloide ou un cristalloide sur le thromboelastogramme avant l'accouchement par cesarienne]
Can J Anesth, March 1, 2007; 54(3): 190 - 195.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
J. Boldt, M. Wolf, and A. Mengistu
A New Plasma-Adapted Hydroxyethylstarch Preparation: In Vitro Coagulation Studies Using Thrombelastography and Whole Blood Aggregometry
Anesth. Analg., February 1, 2007; 104(2): 425 - 430.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
96/4/455    most recent
ael019v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (5)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by von Roten, I.
Right arrow Articles by Spahn, D. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by von Roten, I.
Right arrow Articles by Spahn, D. R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?