Skip Navigation


BJA Advance Access originally published online on February 27, 2007
British Journal of Anaesthesia 2007 98(4):531-538; doi:10.1093/bja/aem006
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
98/4/531    most recent
aem006v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Schumann, S.
Right arrow Articles by Guttmann, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schumann, S.
Right arrow Articles by Guttmann, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Board of Management and Trustees of the British Journal of Anaesthesia 2007. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Moisturizing and mechanical characteristics of a new counter-flow type heated humidifier

S. Schumann1,*, C. A. Stahl1, K. Möller2, H.-J. Priebe1 and J. Guttmann1

1 Department of Anaesthesiology and Intensive Care, Section for Experimental Anaesthesiology, University Hospital Freiburg, Hugstetter Strasse 55, 79106 Freiburg, Germany
2 Department of Biomedical Engineering, University of Applied Sciences Furtwangen, Germany

* Corresponding author: E-mail: stefan.schumann{at}uniklinik-freiburg.de

Background: During mechanical ventilation effective conditioning of inspired air is important. In this respect, conventional humidifiers do not perform optimally. By design, a counter-flow-type humidifier should improve humidification and heating, but may increase resistance.

Methods: We investigated mechanical impedance and work of breathing (using pressure-flow characteristics and additional pressure–time product) of a new counter-flow-type humidifier, a conventional heated humidifier, and a passive heat and moisture exchanger (HME) in physical models of the respiratory system. We investigated moisturizing performance (amount of vaporized water at different air flows and ventilatory frequencies) of the two heated humidifiers. Ease of breathing through both heated humidifiers was investigated in 12 healthy volunteers blinded to the type of humidifier.

Results: Moisturizing performance of the conventional heated humidifier was flow-independent (approximately 32.5 mg vaporized water per breath at inspiratory flow rates of 30–120 litre min – 1; P > 0.05) but decreased (10%; P < 0.0001) with increasing ventilatory rates (12–20 min – 1). In contrast, moisturizing performance of the counter-flow-type humidifier (approximately 33.5 mg vaporized water per breath) was both flow- and rate-independent (P = 0.75). In addition, the counter-flow humidifier caused less physical work (approximately 25%) and resistance (approximately 50%) (both P < 0.05) than the other two devices. The passive HME displayed the least favourable mechanical characteristics. Ten of 12 volunteers felt breathing through the counter-flow humidifier easier than through the heated humidifier (P < 0.05).

Conclusion: Compared with a conventional humidifier, the new counter-flow-type humidifier displayed improved air conditioning and mechanical characteristics. Its lower resistance, particularly at low airflows, should be of clinical benefit during spontaneous breathing and triggered assisted ventilation.

Keywords: airway, resistance; equipment, heat and moisture exchanger; equipment, heated humidifiers; humidification, efficiency; ventilation, mechanical ventilation support


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.