Skip Navigation


BJA Advance Access originally published online on March 8, 2007
British Journal of Anaesthesia 2007 98(4):442-446; doi:10.1093/bja/aem010
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
98/4/442    most recent
aem010v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Capper, S. J.
Right arrow Articles by Morgan-Hughes, N. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Capper, S. J.
Right arrow Articles by Morgan-Hughes, N. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Board of Management and Trustees of the British Journal of Anaesthesia 2007. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Transoesophageal echocardiography for the detection and quantification of pleural fluid in cardiac surgical patients

S. J. Capper1, J. J. Ross2, E. Sandström3, P. C. Braidley1 and N. J. Morgan-Hughes1,*

1 South Yorkshire Cardiothoracic Centre
2 University of Sheffield Academic Anaesthetic Unit, Northern General Hospital, Sheffield S5 7AU, UK
3 Department of Anaesthesia, Östersunds Hospital, Östersunds, Sweden

* Corresponding author: South Yorkshire Cardiothoracic Centre, Northern General Hospital, Sheffield S5 7AU, UK. E-mail: nick.morgan-hughes{at}sth.nhs.uk

Background: Transoesophageal echocardiography (TOE) can image pleural fluid. Left pleural collections may be easier to detect than right, as the thoracic aorta serves as an acoustic window. Attempts to quantify pleural fluid using TOE are restricted to a case report in which volume was predicted by multiplying maximal cross-sectional area (CSAmax) by axial length (AL). A computed tomography (CT) derived formula for quantifying pleural effusions is maximal effusion depth squared (d2) multiplied by maximal effusion length.

Methods: Eight patients were studied before chest closure following coronary bypass surgery. Fifty millilitre saline aliquots were instilled into the pleural space until detected by TOE. Saline was then instilled up to the next 200 ml increment and further 200 ml aliquots added until it spilled from the pleural space. CSAmax, d and AL were measured for each stage and used to calculate pleural fluid volume.

Results: Median detection volume (range) was 125 ml (50–200) on the left and 225 ml (150–300) on the right (P = 0.016). Volume calculated by CSAmax x AL correlated strongly with actual volume (r2 = 0.93 left and 0.92 right) as did volume calculated by d2 x AL (r2 = 0.86 left and 0.89 right). Mean difference between volume calculated by CSAmax x AL and actual volume was – 51 ml on the left and 45 ml on the right vs – 253 ml on the left and – 212 ml on the right for volume calculated by d2 x AL.

Conclusions: TOE detects small volumes of pleural fluid on both sides of the chest. CSAmax x AL provides a reasonably accurate measure of pleural fluid volume.

Keywords: pleural effusion; pleural fluid; monitoring, transoesophageal echocardiography; surgery, cardiac


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.