Skip Navigation


BJA Advance Access originally published online on September 2, 2005
British Journal of Anaesthesia 2005 95(5):715-718; doi:10.1093/bja/aei226
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
95/5/715    most recent
aei226v1
Right arrow E-Letters: Submit a response to the article
Right arrow E-letters: View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (1)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Biswas, B. K.
Right arrow Articles by Bhattarai, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Biswas, B. K.
Right arrow Articles by Bhattarai, B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Board of Management and Trustees of the British Journal of Anaesthesia 2005. All rights reserved. For Permissions, please e-mail: journal.permissions@oxfordjournals.org

Intubating laryngeal mask for airway management in lateral decubitus state: comparative study of right and left lateral positions

B. K. Biswas*, B. Agarwal, P. Bhattacharyya, U. K. Badhani and B. Bhattarai

Department of Anaesthesia and Critical Care, B.P.Koirala Institute of Health Sciences, Dharan-18, Nepal

* Corresponding author. E-mail: binsaiims{at}sify.com

Background. The intubating laryngeal mask has been used for the emergency management of the airway in patients placed in the lateral decubitus position. We have conducted this prospective study to compare the feasibility of placement of an intubating laryngeal mask and blind tracheal intubation guided by the intubating laryngeal mask in patients placed in the right and the left lateral positions.

Methods. A total of 82 adults of both sexes with normal airways, scheduled for cholecystectomy, were allocated randomly to be placed in either the right (n=41) or left (n=41) lateral position for the insertion of an intubating laryngeal mask and blind tracheal intubation guided by the intubating laryngeal mask under balanced general anaesthesia. A sequence of standard manoeuvres was performed after each failed attempt at intubating laryngeal mask placement and intubation.

Results. The intubating laryngeal mask was placed in all patients at the first attempt. Ventilation of the lungs through the intubating laryngeal mask was possible in 40 patients (97.5%) from each group after the first attempt at insertion (P=1). Following adjustments, adequate ventilation could be achieved in all patients. The first attempt success rates of blind tracheal intubation were 85.3% (35/41) and 87.8% (36/41) in the right and left lateral groups, respectively (P=1). The remaining patients from both groups (except for one patient in the left lateral group who had a failed intubation) were intubated at the second attempt.

Conclusion. Insertion of the intubating laryngeal mask and blind tracheal intubation through it in the lateral position is feasible in patients with normal airways. These procedures have a high and comparable success rate when patients are placed in the right and left lateral positions.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


E-letters:

Read all E-letters

Intubating LMA in Lateral Position - Method of Insertion
Vijaya K Ramaiah
British Journal of Anaesthesia, 10 Oct 2005 [Full text]


Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.