Skip Navigation


BJA Advance Access originally published online on December 10, 2004
British Journal of Anaesthesia 2005 94(3):385-389; doi:10.1093/bja/aei045
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
94/3/385    most recent
aei045v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (18)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Goldmann, K.
Right arrow Articles by Jakob, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goldmann, K.
Right arrow Articles by Jakob, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Board of Management and Trustees of the British Journal of Anaesthesia 2004. All rights reserved. For Permissions, please e-mail: journal.permissions{at}oupjournals.org

Size 2 ProSealTM laryngeal mask airway: a randomized, crossover investigation with the standard laryngeal mask airway in paediatric patients

K. Goldmann*,{dagger} and C. Jakob

Department of Anaesthesia and Intensive Care Therapy, Philipps University Marburg, 35033 Marburg, Germany

* Corresponding author. E-mail: kaigoldmann1{at}aol.com

Background. One of the main concerns with the use of the standard laryngeal mask airway (SLMA) in small infants is that its low-pressure seal might be inadequate for positive pressure ventilation so that there is a risk of gas leakage into the stomach with the subsequent risk of regurgitation. The new ProSealTM LMA (PLMA) has been shown to form a more effective seal than the SLMA and to facilitate gastric tube placement in adults. The first paediatric size PLMA became available recently.

Methods. Thirty anaesthetized, non-paralysed children aged 46 (19) months, weighing 16 (10–21) kg, were studied. The SLMA and PLMA were inserted in random order into each patient. Airway leak pressure and maximum tidal volume were measured. Ease of insertion, quality of initial airway and fibreoptic position were also determined. Gastric tube placement was assessed for the PLMA.

Results. The airway leak pressure and maximum tidal volume were significantly higher for the PLMA (P=0.001). Ease of insertion and quality of initial airway were similar for both devices. Air entry into the stomach occurred more frequently with the SLMA (P=0.005). Gastric tube placement was possible in all patients.

Conclusions. The size 2 PLMA offered some advantages over the same size of SLMA in this crossover investigation. The high reliability of gastric tube placement and the significantly increased airway leak pressure might have important implications for use of this device for positive pressure ventilation in infants.

{dagger} Declaration of interest. K.G. has received an honorarium for lecturing at regional meetings from LMA Vertriebs-GmbH, the German distributor of the PLMA.

{ddagger} LMA® is the property of Intavent Limited.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
M. Micaglio, R. Bonato, M. De Nardin, M. Parotto, D. Trevisanuto, V. Zanardo, N. Doglioni, and C. Ori
Prospective, randomized comparison of ProSealTM and ClassicTM laryngeal mask airways in anaesthetized neonates and infants
Br. J. Anaesth., August 1, 2009; 103(2): 263 - 267.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. Micaglio, M. Parotto, D. Trevisanuto, and V. Zanardo
Size 1 ProSealTM Laryngeal Mask Airway in Neonates
Anesth. Analg., October 1, 2006; 103(4): 1044 - 1045.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
K. Goldmann, C. Roettger, and H. Wulf
The Size 11/2 ProSealTM Laryngeal Mask Airway in Infants: A Randomized, Crossover Investigation with the ClassicTM Laryngeal Mask Airway
Anesth. Analg., February 1, 2006; 102(2): 405 - 410.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
K. Goldmann, C. Roettger, and H. Wulf
Use of the ProSealTM laryngeal mask airway for pressure-controlled ventilation with and without positive end-expiratory pressure in paediatric patients: a randomized, controlled study
Br. J. Anaesth., December 1, 2005; 95(6): 831 - 834.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
M. Lopez-Gil, J. Brimacombe, and G. Garcia
A randomized non-crossover study comparing the ProSealTM and ClassicTM laryngeal mask airway in anaesthetized children
Br. J. Anaesth., December 1, 2005; 95(6): 827 - 830.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.