Skip Navigation


BJA Advance Access originally published online on November 19, 2004
British Journal of Anaesthesia 2005 94(2):229-233; doi:10.1093/bja/aei029
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
94/2/229    most recent
aei029v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (5)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by McLeod, G. A.
Right arrow Articles by Columb, M. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McLeod, G. A.
Right arrow Articles by Columb, M. O.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Board of Management and Trustees of the British Journal of Anaesthesia 2004

Is the clinical efficacy of epidural diamorphine concentration-dependent when used as analgesia for labour?{dagger}

G. A. McLeod1,*, B. Munishankar1 and M. O. Columb2

1 Department of Anaesthetics, Ninewells Hospital and Medical School, Dundee DD1 9SY, UK. 2 Departments of Anaesthesia and Intensive Care Medicine, South Manchester University Hospital, Wythenshawe, UK

* Corresponding author. E-mail: g.a.mcleod{at}dundee.ac.uk

Background. The physicochemical properties of diamorphine (3,6-diacetylmorphine) enhance its bioavailability compared with more lipid-soluble opioids when administered into the epidural space. However, the influence of concentration, volume or mass on the clinical efficacy of diamorphine is not known.

Method. In this double-blind, randomized, prospective study, 62 women in active labour and ≤5 cm cervical dilatation were recruited to determine whether the mode of action of diamorphine in the epidural space is concentration-dependent. After insertion of a lumbar epidural catheter, patients received epidural diamorphine 3 mg either as a high-volume, low-concentration solution (group A) or a low-volume, high-concentration solution (group B). The concentration of diamorphine was determined by the response of the previous patient in the same group using up–down sequential allocation. Pain corresponding to the previous contraction was assessed using a 100-mm visual analogue score and effective analgesia was defined as ≤10 mm within 30 min of epidural injection.

Results. There was no significant difference in EC50 for diamorphine between the groups: the difference was 15.0 µg ml–1 (95% CI –40.3 to 10.3). The EC50 for group A was 237.5 µg ml–1 (95% CI 221.2 to 253.8) and the EC50 for group B was 252.5 µg ml–1 (95% CI 232.2 to 272.8). The EC50 ratio was 0.95 (95% CI 0.87 to 1.06). The groups exhibited parallelism (P=0.98). The overall EC50 for all data was 244.2 µg ml–1 (95% CI 230.8 to 257.2).

Conclusion. We conclude that diamorphine provides analgesia in labour by a concentration-dependent effect.

{dagger} This work was presented by Dr G. A. McLeod to the Anaesthetic Research Society, Aberdeen, 2004.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
G. A. McLeod, B. Munishankar, and M. O. Columb
An isobolographic analysis of diamorphine and levobupivacaine for epidural analgesia in early labour
Br. J. Anaesth., April 1, 2007; 98(4): 497 - 502.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.