BJA Advance Access originally published online on October 1, 2004
British Journal of Anaesthesia 2004 93(6):782-788; doi:10.1093/bja/aeh280
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
© The Board of Management and Trustees of the British Journal of Anaesthesia 2004
Prediction of fluid responsiveness in patients during cardiac surgery
1 Department of Anaesthesiology and 2 Department of Thoracic and Cardiovascular Surgery, Rheinisch-Westfälische Technische Hochschule, Aachen, Germany
* Corresponding author: Klinik für Anästhesiologie, Universitätsklinikum der RWTH Aachen, Pauwelsstrasse 30, D-52074 Aachen, Germany. E-mail: srex{at}ukaachen.de
Background. Left ventricular stroke volume variation (SVV) has been shown to be a predictor of fluid responsiveness in various subsets of patients. However, the accuracy and reliability of SVV are unproven in patients ventilated with low tidal volumes.
Methods. Fourteen patients were studied immediately after coronary artery bypass grafting (CABG). All patients were mechanically ventilated in pressure-controlled mode [tidal volume 7.5 (1.2) ml kg1]. In addition to standard haemodynamic monitoring, SVV was assessed by arterial pulse contour analysis. Left ventricular end-diastolic area index (LVEDAI) was determined by transoesophageal echocardiography. A transpulmonary thermodilution technique was used for measurement of cardiac index (CI), stroke volume index (SVI) and intrathoracic blood volume index (ITBI). All variables were assessed before and after a volume shift induced by tilting the patients from the anti-Trendelenburg (30° head up) to the Trendelenburg position (30° head down).
Results. After the change in the Trendelenburg position, SVV decreased significantly, while CI, SVI, ITBI, LVEDAI, central venous pressure (CVP) and pulmonary artery occlusion pressure (PAOP) increased significantly. Changes in SVI were significantly correlated to changes in SVV (r=0.70; P<0.0001) and to changes in LVEDAI, ITBI, CVP and PAOP. Only prechallenge values of SVV were predictive of changes in SVI after change from the anti-Trendelenburg to the Trendelenburg position.
Conclusions. In patients after CABG surgery who were ventilated with low tidal volumes, SVV enabled prediction of fluid responsiveness and assessment of the haemodynamic effects of volume loading.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
M. Cannesson, O. Desebbe, P. Rosamel, B. Delannoy, J. Robin, O. Bastien, and J.-J. Lehot Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre Br. J. Anaesth., August 1, 2008; 101(2): 200 - 206. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. E. C. de Waal, S. Rex, C. L. J. J. Kruitwagen, C. J. Kalkman, and W. F. Buhre Stroke volume variation obtained with FloTrac/VigileoTM fails to predict fluid responsiveness in coronary artery bypass graft patients Br. J. Anaesth., May 1, 2008; 100(5): 725 - 726. [Full Text] [PDF] |
||||
![]() |
M. Cannesson, J. Slieker, O. Desebbe, C. Bauer, P. Chiari, R. Henaine, and J.-J. Lehot The Ability of a Novel Algorithm for Automatic Estimation of the Respiratory Variations in Arterial Pulse Pressure to Monitor Fluid Responsiveness in the Operating Room Anesth. Analg., April 1, 2008; 106(4): 1195 - 1200. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Kubitz, T. Annecke, S. Forkl, G. I. Kemming, N. Kronas, A. E. Goetz, and D. A. Reuter Validation of pulse contour derived stroke volume variation during modifications of cardiac afterload Br. J. Anaesth., May 1, 2007; 98(5): 591 - 597. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Solus-Biguenet, M. Fleyfel, B. Tavernier, E. Kipnis, J. Onimus, E. Robin, G. Lebuffe, C. Decoene, F. R. Pruvot, and B. Vallet Non-invasive prediction of fluid responsiveness during major hepatic surgery Br. J. Anaesth., December 1, 2006; 97(6): 808 - 816. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Mekontso-Dessap, L. Tual, M. Kirsch, G. D'Honneur, D. Loisance, L. Brochard, and J.-L. Teboul B-type natriuretic peptide to assess haemodynamic status after cardiac surgery Br. J. Anaesth., December 1, 2006; 97(6): 777 - 782. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Kubitz, T. Annecke, G. I. Kemming, S. Forkl, N. Kronas, A. E. Goetz, and D. A. Reuter The influence of positive end-expiratory pressure on stroke volume variation and central blood volume during open and closed chest conditions. Eur. J. Cardiothorac. Surg., July 1, 2006; 30(1): 90 - 95. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. Reuter, M. S. G. Goepfert, T. Goresch, M. Schmoeckel, E. Kilger, and A. E. Goetz Assessing fluid responsiveness during open chest conditions Br. J. Anaesth., March 1, 2005; 94(3): 318 - 323. [Abstract] [Full Text] [PDF] |
||||