British Journal of Anaesthesia, 2004, Vol. 92, No. 1 131-133
© 2004 The Board of Management and Trustees of the British Journal of Anaesthesia
Short Communications |
Endotoxaemia during left ventricular assist device insertion: relationship between risk factors and outcome
1 Department of Anaesthesiaand 2 Department of Surgery, Columbia University College of Physicians and Surgeons, 630, West 168th Street, New York, NY 10032, USA
*Corresponding author. E-mail: cathomalley@hotmail.com
Background. Endotoxaemia, caused by splanchnic ischaemia during surgery, is believed to trigger systemic inflammation and cause postoperative organ dysfunction. A relationship between the plasma concentration of endotoxin during surgery and known risk factors for postoperative morbidity and mortality (e.g. age, abnormal gastric tonometric variables) and adverse outcome after surgery has not been demonstrated.
Methods. In a prospective study, the plasma concentration of endotoxin was measured in 12 patients undergoing implantation of a left ventricular assist device. Automated air gastric tonometry was performed in all patients. The relationship between plasma endotoxin concentration, risk factors, and postoperative outcome was explored.
Results. Carbon dioxide gap increased from 0.7 (0.3) to 3.6 (1.6) kPa at the end of surgery. Endotoxin was detected in one of 12 patients at baseline and in nine of 12 patients at the end of surgery (P=0.003). A high plasma concentration of endotoxin at the end of surgery was associated with a higher carbon dioxide gap (r=0.59, P<0.05), and a higher postoperative multiple organ dysfunction score (r=0.7, P=0.01).
Conclusions. The finding of an association between high intraoperative plasma concentrations of endotoxin, abnormal gastric tonometric variables and adverse outcome supports the view that endotoxaemia is caused by gut hypoperfusion during surgery and is associated with postoperative organ dysfunction.
Br J Anaesth 2004; 92: 1313
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
E. Bennett-Guerrero, H. P. Grocott, J. H. Levy, K. A. Stierer, C. W. Hogue, A. T. Cheung, M. F. Newman, A. A. Carter, D. P. Rossignol, and C. D. Collard A Phase II, Double-Blind, Placebo-Controlled, Ascending-Dose Study of Eritoran (E5564), a Lipid A Antagonist, in Patients Undergoing Cardiac Surgery with Cardiopulmonary Bypass Anesth. Analg., February 1, 2007; 104(2): 378 - 383. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. A. Hessel II Abdominal Organ Injury After Cardiac Surgery Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2004; 8(3): 243 - 263. [Abstract] [PDF] |
||||
![]() |
C. Hamilton-Davies, M. Mythen, and C. O'Malley Endotoxaemia during left ventricular assist device insertion Br. J. Anaesth., June 1, 2004; 92(6): 907 - 907. [Full Text] [PDF] |
||||
![]() |
R. K. Rao, A. Seth, and P. Sheth Recent Advances in Alcoholic Liver Disease I. Role of intestinal permeability and endotoxemia in alcoholic liver disease Am J Physiol Gastrointest Liver Physiol, June 1, 2004; 286(6): G881 - G884. [Abstract] [Full Text] [PDF] |
||||