British Journal of Anaesthesia, 2003, Vol. 90, No. 1 62-65
© 2003 The Board of Management and Trustees of the British Journal of Anaesthesia
Clinical Investigations |
The swoosh testan evaluation of a modified whoosh test in children
Nuffield Department of Anaesthetics, John Radcliffe Hospital, Headley Way, Headington, Oxford OX3 9DU, UK E-mail: caroline.rob@virgin.net
Background. Caudal analgesia is widely used in paediatric anaesthetic practice. In adults, the whoosh test has been recommended as a guide to successful needle insertion, but it has not been extensively studied in paediatric patients. We have investigated a modification of the whoosh test, which we have christened the swoosh test. It avoids the injection of air by performing auscultation during injection of the local anaesthetic solution. We have compared it with clinical judgement of correct placement.
Methods. We studied 113 children undergoing elective surgery. During insertion of the caudal block, a stethoscope was placed over the lower lumbar spine and the presence or absence of an audible swoosh noted. The operators clinical impression of successful insertion was also recorded.
Results. The overall success rate of caudal anaesthesia was 95.6%. Of the 108 patients with a successful block, 98 had a positive swoosh test. There were no false positive results. Calculations show the swoosh test to have a sensitivity of 91%, a specificity of 100% and a positive predictive value of 100%.
Conclusions. The swoosh test is a simple and accurate test to confirm successful caudal insertion in children, and is especially useful as a teaching aid for anaesthetists new to the technique.
Br J Anaesth 2003; 90: 625
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
D. Schwartz, K. Raghunathan, S. Dunn, and N. R. Connelly Ultrasonography and Pediatric Caudals Anesth. Analg., January 1, 2008; 106(1): 97 - 99. [Abstract] [Full Text] [PDF] |
||||