British Journal of Anaesthesia, 2002, Vol. 88, No. 4 540-545
© 2002 The Board of Management and Trustees of the British Journal of Anaesthesia
Laboratory Investigations |
Increased airway resistance during xenon anaesthesia in pigs is attributed to physical properties of the gas
1Clinic for Anaesthesiology, Klinikum der RWTH Aachen, Pauwelsstr. 30, D-52074 Aachen, Germany*Corresponding author
Background. In this study we investigated the effects of the physical properties of xenon on respiratory mechanisms in pigs.
Methods. With institutional approval, 10 female pigs (mean 25.2 (SD 2.5) kg) were anaesthetized with thiopental, remifentanil, and pancuronium. Gas flow and pressure were recorded continuously at the proximal end of the tracheal tube during constant flow ventilation for control, with 100% oxygen (control), followed by 1.5% isoflurane in 70/30% nitrogen/oxygen, 1.0% isoflurane in 70/30% nitrous oxide/oxygen, and 70/30% xenon/oxygen in random order. Compliance (C) and resistance (R) were calculated using a single compartment model. Resistance was corrected for gas viscosities
and also for densities
and viscosities
as (
*
)1/2 to compare assumptions of laminar and mixed flow in the airways.
Results. With constant flow ventilation, xenon increases inspiratory pressure compared with other gas mixtures. There were no significant differences in resistance, corrected for laminar or mixed flow, between the gas mixtures. Xenon anaesthesia did not affect compliance.
Conclusions. The increase in airway pressure observed with xenon anaesthesia is attributed completely to its higher density and viscosity. Therefore, determination of airway resistance must take into account the physical properties of the gas. Xenon does not exert any major effect on airway diameter.
Br J Anaesth 2002; 88: 5405
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
M M Theisen, M Maas, M A G. Hartlage, F Ploner, S M Niehues, H K Van Aken, T P Weber, and J K Unger Ventral recumbency is crucial for fast and safe orotracheal intubation in laboratory swine Lab Anim, January 1, 2009; 43(1): 96 - 101. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Bayat, L. Porra, H. Suhonen, C. Nemoz, P. Suortti, and A. R. A. Sovijarvi Differences in the time course of proximal and distal airway response to inhaled histamine studied by synchrotron radiation CT J Appl Physiol, June 1, 2006; 100(6): 1964 - 1973. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. D. Sanders, D. Ma, and M. Maze Xenon: elemental anaesthesia in clinical practice Br. Med. Bull., February 22, 2005; 71(1): 115 - 135. [Abstract] [Full Text] [PDF] |
||||