Skip Navigation

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (28)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Sleigh, J. W.
Right arrow Articles by Smith, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sleigh, J. W.
Right arrow Articles by Smith, P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 2001, Vol. 86, No. 1 50-58
© 2001 The Board of Management and Trustees of the British Journal of Anaesthesia

Comparison of changes in electroencephalographic measures during induction of general anaesthesia: influence of the gamma frequency band and electromyogram signal

J. W. Sleigh1, D. A. Steyn-Ross2, M. L. Steyn-Ross2, M. L. Williams1 and P. Smith1

1Department of Anaesthesia, Waikato Hospital, Hamilton, New Zealand. 2Department of Physics and Medical Electronics, University of Waikato, Hamilton, New Zealand*Corresponding author

Recent research has shown that high-frequency, gamma-band electroencephalographic (EEG) oscillations (40–60 Hz) may be an important marker of the conscious state. We compared the ability of the bispectral index (BIS) to distinguish the awake and anaesthetized states during the induction of general anaesthesia with: (i) components of the BIS (BetaRatio, SynchFastSlow); (ii) a new EEG variable—the median frequency of the first time derivative of the EEG signal (SE50d); and (iii) the SE50d derived from an EEG signal that has had the frequencies above 30 Hz removed (SE50d30Hz). Two groups of subjects were studied: (i) nine volunteers undergoing a short propofol infusion until loss of response to verbal command, and (ii) 84 patients undergoing routine anaesthesia for a variety of surgical procedures. In the volunteer group, the changes in the BetaRatio and SE50d were comparable with changes in the BIS. The changes in the SE50d30Hz were less consistent. In the patient group, the BIS components were equivalent to the BIS in separating the awake from the surgically anaesthetized states (area under receiver operating curve: BIS 0.95, SE50d 0.95, BetaRatio 0.96). Using the submental electromyogram (EMG) signal to estimate the frontalis EMG (30–47 Hz) signal, the changes in EMG signal were, on average, about one-tenth the magnitude of the EEG. We conclude that: (i) there exist simpler derived EEG variables that are similar in accuracy to the BIS; (ii) it is important to avoid filtering out the EEG frequencies above 30 Hz; and (iii) in most patients the confounding effects of the frontalis EMG on the EEG are minimal.

Br J Anaesth 2001; 86: 50–8


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
A. G. Doufas, R. Komatsu, M. Orhan-Sungur, P. Sengupta, A. Wadhwa, E. Mascha, S. L. Shafer, and D. I. Sessler
Neuromuscular Block Differentially Affects Immobility and Cortical Activation at Near-Minimum Alveolar Concentration Anesthesia
Anesth. Analg., October 1, 2009; 109(4): 1097 - 1104.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
A. A. Dahaba, G. X. Xu, Q. H. Liu, J. X. Xue, and H. Metzler
Bispectral Index Monitoring of a Narcolepsy-Cataplexy Episode During Regional Anesthesia
Anesth. Analg., February 1, 2009; 108(2): 613 - 615.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
M. Kawaguchi, I. Takamatsu, K. Masui, and T. Kazama
Effect of landiolol on bispectral index and spectral entropy responses to tracheal intubation during propofol anaesthesia
Br. J. Anaesth., August 1, 2008; 101(2): 273 - 278.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
A A Dahaba, H C Worm, S M Zhu, F P Bao, A Salah, S Zakaria, H Bornemann, V Stadlbauer, P H Rehak, H Metzler, et al.
Sensitivity and specificity of bispectral index for classification of overt hepatic encephalopathy: a multicentre, observer blinded, validation study
Gut, January 1, 2008; 57(1): 77 - 83.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
V. Bonhomme and P. Hans
Muscle relaxation and depth of anaesthesia: where is the missing link?
Br. J. Anaesth., October 1, 2007; 99(4): 456 - 460.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
A. Ekman, E. Stalberg, E. Sundman, L. I. Eriksson, L. Brudin, and R. Sandin
The Effect of Neuromuscular Block and Noxious Stimulation on Hypnosis Monitoring During Sevoflurane Anesthesia
Anesth. Analg., September 1, 2007; 105(3): 688 - 695.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
A. A. Dahaba, U. Lischnig, R. Kronthaler, H. Bornemann, V. Georgiev, P. H. Rehak, and H. Metzler
Bispectral-index-guided versus clinically guided remifentanil/propofol analgesia/sedation for interventional radiological procedures: an observer-blinded randomized study.
Anesth. Analg., August 1, 2006; 103(2): 378 - 84, table of contents.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
N. Liu, T. Chazot, I. Huybrechts, J.-D. Law-Koune, L. Barvais, and M. Fischler
The Influence of a Muscle Relaxant Bolus on Bispectral and Datex-Ohmeda Entropy Values During Propofol-Remifentanil Induced Loss of Consciousness
Anesth. Analg., December 1, 2005; 101(6): 1713 - 1718.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
A. A. Dahaba
Different Conditions That Could Result in the Bispectral Index Indicating an Incorrect Hypnotic State
Anesth. Analg., September 1, 2005; 101(3): 765 - 773.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
A. A. Dahaba, M. Mattweber, A. Fuchs, W. Zenz, P. H. Rehak, W. F. List, and H. Metzler
The Effect of Different Stages of Neuromuscular Block on the Bispectral Index and the Bispectral Index-XP Under Remifentanil/Propofol Anesthesia
Anesth. Analg., September 1, 2004; 99(3): 781 - 787.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
Y. Morimoto, S. Hagihira, Y. Koizumi, K. Ishida, M. Matsumoto, and T. Sakabe
The Relationship Between Bispectral Index and Electroencephalographic Parameters During Isoflurane Anesthesia
Anesth. Analg., May 1, 2004; 98(5): 1336 - 1340.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
A. Miller, J. W. Sleigh, J. Barnard, and D. A. Steyn-Ross
Does bispectral analysis of the electroencephalogram add anything but complexity?{dagger}
Br. J. Anaesth., January 1, 2004; 92(1): 8 - 13.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
E. Gurses, H. Sungurtekin, E. Tomatir, and H. Dogan
Assessing Propofol Induction of Anesthesia Dose Using Bispectral Index Analysis
Anesth. Analg., January 1, 2004; 98(1): 128 - 131.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. Hagihira, M. Takashina, T. Mori, T. Mashimo, and I. Yoshiya
Practical Issues in Bispectral Analysis of Electroencephalographic Signals
Anesth. Analg., October 1, 2001; 93(4): 966 - 970.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.