Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (6)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Scheeren, TWL.
Right arrow Articles by Arndt, J. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Scheeren, TWL.
Right arrow Articles by Arndt, J. O.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, Vol 80, Issue 4 521-524, Copyright © 1998 by The Board of Management and Trustees of the British Journal of Anaesthesia


EQUIPMENT

Error in measurement of oxygen and carbon dioxide concentrations by the DeltatracII metabolic monitor in the presence of desflurane

TWL. Scheeren, M. Krossa, P. Merilainen and J. O. Arndt
Department of Experimental Anaesthesiology, Heinrich-Heine-University, Dusseldorf, Germany; Datex-Engstrom Division, Instrumentarium Corp., Helsinki, Finland

In experiments in dogs on the metabolic effects of inhalation anaesthetics, we noticed that in the presence of desflurane, oxygen uptake (VO2) measured with the Deltatracll metabolic monitor seemingly increased whereas it decreased when determined independently by the Fick principle. This difference remained even after correction for changes in gas concentration on addition of an inhalation anaesthetic. Therefore, we suspected that desflurane interferes with the measurement of gas concentrations. Using different precision gases, we found that desflurane disturbed both the paramagnetic oxygen sensor and the infrared carbon dioxide detector so that the measured oxygen (when FIO2 was > 0.21) and carbon dioxide concentrations were greater than expected. These errors multiply in the computing process of oxygen uptake by the DeltatracII. When the DeltatracII is to be used during inhalation anaesthesia, its results should be corrected for the presence of an anaesthetic gas. More importantly, corrections must also be made for measurement errors of the oxygen and carbon dioxide sensors, unless the device has been equipped with a modified (nickel membrane) oxygen sensor insensitive to the presence of volatile agents.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
G. Briassoulis, P. Briassoulis, E. Michaeloudi, D.-M. Fitrolaki, A.-M. Spanaki, and E. Briassouli
The Effects of Endotracheal Suctioning on the Accuracy of Oxygen Consumption and Carbon Dioxide Production Measurements and Pulmonary Mechanics Calculated by a Compact Metabolic Monitor
Anesth. Analg., September 1, 2009; 109(3): 873 - 879.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
A. Gonzalez-Arevalo, J. I. Gomez-Arnau, J. delaCruz, F. Lacoma, P. Galdos, and S. Garcia-del-Valle
Oxygen Consumption Measurement: Agreement Between the Closed-Circuit PhysioFlex Anesthesia Machine and the Deltatrac II Indirect Calorimeter
Anesth. Analg., December 1, 2003; 97(6): 1680 - 1685.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.