Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (16)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Kumar, N.
Right arrow Articles by McCarthy, G. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kumar, N.
Right arrow Articles by McCarthy, G. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, Vol 77, Issue 4 488-491, Copyright © 1996 by The Board of Management and Trustees of the British Journal of Anaesthesia


CLINICAL INVESTIGATIONS

Potency and time course of action of rocuronium during desflurane and isoflurane anaesthesia

N. Kumar, R. K. Mirakhur, MJJ. Symington and G. J. McCarthy
Department of Anaesthetics, The Queen's University of Belfast, Whitla Medical Building, 97 Lisburn Road, Belfast BT9 7BL; Department of Clinical Anaesthesia, Belfast City Hospital, Belfast

We have studied the potency and onset and duration of action of rocuronium in patients anaesthetized with 1 MAC of desflurane or isoflurane (in 66% nitrous oxide). Potency was estimated using the single bolus dose technique. Neuromuscular block was measured by stimulation of the ulnar nerve and recording the force of contraction of the adductor pollicis muscle. The ED50 and ED95 of rocuronium were estimated as 138 (95% confidence limits 117-162) micrograms kg-1 and 281 (241-328) micrograms kg-1, and 126 (105-151) micrograms kg-1 and 283 (236-339) micrograms kg-1 during desflurane and isoflurane anaesthesia, respectively. The mean times to onset of maximum block after rocuronium 0.6 mg kg-1 were 1.0 (SD 0.10) min and 1.1 (0.15) min, respectively, during anaesthesia with desflurane and isoflurane. The respective times to recovery of T1 (the first response in the train-of- four (TOF) stimulation) to 25% and 90% were 36 (8.3) min and 54 (15.4) min during desflurane anaesthesia and 31 (8.2) min and 45 (12.7) min during isoflurane anaesthesia. The times to recovery of the TOF ratio to 0.7 were 66 (13.4) min and 52 (16.3) min and the 25-75% recovery indices 14 (5.3) min and 10 (3.2) min, respectively, in the desflurane and isoflurane groups. There were no differences in the estimated potency or onset of action of rocuronium during desflurane and isoflurane anaesthesia. However, duration of action tended to be longer curing desflurane anaesthesia although only the differences in times to TOF ratio of 0.7 and the recovery indices were close to being significantly different (P = 0.0503 and 0.0560).
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
T. J. Zhou, M. Coloma, P. F. White, J. Tang, T. Webb, J. E. Forestner, N. B. Greilich, and L. L. Duffy
Spontaneous Recovery Profile of Rapacuronium During Desflurane, Sevoflurane, or Propofol Anesthesia for Outpatient Laparoscopy
Anesth. Analg., September 1, 2000; 91(3): 596 - 600.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
T. Heier and J. E. Caldwell
Rapid Tracheal Intubation with Large-Dose Rocuronium: A Probability-Based Approach
Anesth. Analg., January 1, 2000; 90(1): 175 - 175.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.