Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (12)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by HOPE, D. A.
Right arrow Articles by MAPLESON, W. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by HOPE, D. A.
Right arrow Articles by MAPLESON, W. W.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 1995, Vol. 74, No. 5 538-543
© 1995 The Board of Management and Trustees of the British Journal of Anaesthesia


research-article

Non-invasive estimation of venous admixture: validation of a new formula

D. A. HOPE, BM, FRCA, B. J. JENKINS, MB, BS, FRCA, N. WILLIS, MSC, FIMLS, H. MADDOCK, BM. FRCA and W. W. MAPLESON, DSC, FINSTP

Department of Anaesthetics, University Hospital of Wales Heath Park, Cardiff CF4 4XW
Department of Medical Biochemistry, University Hospital of Wales Heath Park, Cardiff CF4 4XW
Department of Anaesthetics and Intensive Care Medicine, University of Wales College of Medicine, University Hospital of Wales Heath Park, Cardiff CF4 4XN

We have developed a computer program that estimates venous admixture (intra-pulmonary shunt) from four measurements: haemoglobin concentration, end-tidal carbon dioxide tension (PE'co2), fractional inspired oxygen concentration (Flo2 and pulse oximetry (Spo2 The formula was tested on patients in an intensive therapy unit by using it to estimate shunt while it was measured simultaneously by a standard, invasive method. A total of 101 measurements were made in 29 patients. After correcting the systematic errors in the assumed differences between PE'co2 and arterial PCO2 and between Spo2 and co-oximetrically measured Sao2 and correcting for a trend in the arteriovenous oxygen concentration difference (C(a-Formula) with shunt, the bias of the non-invasive minus invasive shunt differences was negligible, with no significant dependence on shunt. The limits of agreement were then ±16% shunt overall (±13% within patients). When Sao2 was used instead of Spo2' the limits were ±11% (±8% within patients). (Br. J. Anaesth. 1995; 74: 538%543)


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
H. J. G. and R. J. J.
Modelling: a core technique in anaesthesia and critical care research.
Br. J. Anaesth., November 1, 2006; 97(5): 589 - 592.
[Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
H L Smith and J G Jones
Non-invasive assessment of shunt and ventilation/perfusion ratio in neonates with pulmonary failure
Arch. Dis. Child. Fetal Neonatal Ed., September 1, 2001; 85(2): F127 - 132.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.