Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (11)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by HAYNES, S. R.
Right arrow Articles by TANSEY, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by HAYNES, S. R.
Right arrow Articles by TANSEY, P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 1992, Vol. 69, No. 6 599-601
© 1992 The Board of Management and Trustees of the British Journal of Anaesthesia


research-article

ACCURACY OF COAGULATION STUDIES PERFORMED ON BLOOD SAMPLES OBTAINED FROM ARTERIAL CANNULAE

S. R. HAYNES, M.B., CH.B., M.R.C.O.G., F.F.A.R.C.S.I., F.R.C.ANAES.1, W. ALLARDYCE, B. COWAN, M.B., CH.B., B.SC., F.R.C.ANAES.1 and P. TANSEY, M.B., CH.B., F.R.C.P.(GLASGOW), F.R.C.PATH.2

1Division of Anaesthesia Langside, Glasgow G42 9TY
2Department of Haematology, Victoria Infirmary Langside, Glasgow G42 9TY

We have assessed the accuracy of coagulation studies in blood obtained from intra-arterial cannulae. Paired samples were studied in blood from 39 patients receiving intensive care; one sample was obtained by venepuncture and the other from an intra-arterial cannula after the apparatus deadspace plus 5 ml of blood had been discarded. Activated partial thromboplastin time (APTT) (with throm-boplastin routinely used in our laboratory), pro-thrombin time (PT), thrombin time (TT), fibrinogen and heparin assays were measured on each sample. In 37 sample pairs, APTT was measured also using a different thromboplastin. The median difference between the sample pairs was 5.5 s for APTT (P = 0.032) and 1.0 s (P = 0.048) for TT, the times for arterial cannula samples being longer. There was no significant difference between arterial cannula and venepuncture samples for PT or fibrinogen concentration. Heparin assays revealed heparin contamination in samples obtained from arterial can-nulae in 15 of 30 patients not receiving heparin. It is concluded that, when coagulation studies are performed using the techniques used routinely in our laboratory, a blood sample from an arterial cannula may give clinically misleading information because of contamination with small amounts of heparin, and that separate venepuncture is recommended.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Crit Care NurseHome page
L. K. K. Prue-Owens
Use of Peripheral Venous Access Devices for Obtaining Blood Samples for Measurement of Activated Partial Thromboplastin Times
Crit. Care Nurse, February 1, 2006; 26(1): 30 - 38.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
J. M. Brown and G. Dimeski
Contamination of coagulation tests with heparin from blood gas samples
Br. J. Anaesth., October 1, 2001; 87(4): 628 - 629.
[Abstract] [Full Text] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.