Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by LAMB, K.
Right arrow Articles by JANICKI, P. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by LAMB, K.
Right arrow Articles by JANICKI, P. K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 1992, Vol. 69, No. 2 143-147
© 1992 The Board of Management and Trustees of the British Journal of Anaesthesia


research-article

THE LARYNGEAL MASK AIRWAY FOR INTRAOCULAR SURGERY: EFFECTS ON INTRAOCULAR PRESSURE AND STRESS RESPONSES

K. LAMB, F.R.C.ANAES.*, M. F. M. JAMES, PH.D., F.R.C.ANAES.1 and P. K. JANICKI, M.D., PH.D.

Department of Anaesthesia, University of Cape Town Medical School Observatory 7925, Cape, South Africa

1Correspondence to M.F.M.J

Tracheal intubation, performed routinely during general anaesthesia in patients undergoing intraocular surgery, may have adverse effects on cardiovascular function and intraocular pressure. This study assessed the suitability of the laryngeal mask airway (LMA) as a substitute for tracheal; intubation. Intraocular and systemic pressor effects, heart rate changes and catecholamine concentrations were measured in two groups of 10 patients receiving standardized anaesthesia with either a trachealtube (TT) or a LMA. There were significantly smaller changes in the pressor responses to insertion and in concentrations of catecholamines at critical times in the anaesthetic sequence in the LMA group. Mean (SEM) rate-pressure product was significantly smaller in the LMA group compared with the TT group after both insertion (8276 (730) vs 13307 (1348), P<0.01) and removal (10 152 (595) vs 14 137 (1044). P < 0.07; of the airway device. The change in intraocular pressure was significantly less in the LMA group at all time points after airway instrumentation than that in the TT group, with the greatest difference after extubation (–2.3 (2.4) mm Hg vs 74.5 (3.4) mm Hg. P < 0.071

*Present address: Department of Anaesthetics, Victoria Infirmary, Glasgow.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.