Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (34)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by KALLI, I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by KALLI, I.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 1989, Vol. 62, No. 2 188-193
© 1989 The Board of Management and Trustees of the British Journal of Anaesthesia


research-article

EFFECT OF SURFACE ELECTRODE POSITIONING ON THE COMPOUND ACTION POTENTIAL EVOKED BY ULNAR NERVE STIMULATION IN ANAESTHETIZED INFANTS AND CHILDREN

I. KALLI, M.D.

Departments of Anaesthesia, Surgical Hospital and Children's Hospital, Helsinki University Central Hospital Finland

The effect of surface electrode positioning on the evoked compound action potential (ECAP) was studied during inhalation anaesthesia without neuromuscular blockade. The ECAP of five fullterm infants (aged 2–20 weeks) and five children (age 1–10 yr) was recorded with a neuromuscular relaxation monitor (Relaxograph, Datex) after supramaximal ulnar nerve stimulation. The five recording electrode positions compared were: thenar (adductor pollicis) v. second finger (TD2); thenar v. second dorsal metacarpal interspace (TM2); hypothenar v. fifth finger (HD5); hypothenar v. fourth dorsal metacarpal interspace (HM4); thenar v. hypothenar (TH). The ECAP was steady at positions TD2 and HD5, but marked variation and baseline drift was found at TM2, HM4 and TH. The ECAP peak-to-peak amplitudes were twice as great in children compared with infants. The hypothenar ECAP was liable to stimulus artefact interference because of the short onset latency at HD5 (2.2(SD 0.4)ms), whereas the adductor pollicis (3.0 (SD 0.5)ms) position (TD2) yielded reliable results.

Address for Correspondence: Helsinki University, Surgical Hospital, Department of Anaesthesia, SF-00130 Helsinki, Finland.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.