Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by SHAH, N. K.
Right arrow Articles by BEDFORD, R. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by SHAH, N. K.
Right arrow Articles by BEDFORD, R. F.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 1989, Vol. 62, No. 2 150-152
© 1989 The Board of Management and Trustees of the British Journal of Anaesthesia


research-article

COMPARISON OF THE BAIN AND THE ADE SYSTEMS DURING CONTROLLED VENTILATION IN ADULTS

N. K. SHAH, M.D., C. J. LOUGHLIN, B.A. and R. F. BEDFORD, M.D.

Department of Anesthesiology and Critical Care Medicine, Memorial Sloan-Kettering Cancer Center Room C-302, 1275 York Avenue, New York NY 10021, U.S.A.
The Department of Anesthesiology, Cornell University Medical College

Correspondence to N.K.S.

It has been suggested that Humphrey's ADE system may be an improvement on the Bain system. To compare their efficiencies we have studied 20 anaesthetized adults who had controlled ventilation established with a circle absorber system at a VE sufficient to maintain normocapnia. Patients were then randomly allocated to either a Bain or an ADE system. Fresh gas flow was sufficient to keep PE CO2 constant for 30 min. The other circuit was then used for an additional 30 min. The required FGF was 54 ml kg–1 min–1 for the Bain system, compared with 67 ml kg–1 min–1 for the ADE system. We conclude that, during controlled ventilation, the ADE system is 25% less efficient than the Bain system.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.