Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (51)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by HORTON, W. A.
Right arrow Articles by CHARTERS, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by HORTON, W. A.
Right arrow Articles by CHARTERS, P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 1989, Vol. 62, No. 1 6-12
© 1989 The Board of Management and Trustees of the British Journal of Anaesthesia


research-article

DEFINING A STANDARD INTUBATING POSITION USING "ANGLE FINDER"

W. A. HORTON, B.D.S., M.B., CH.B., F.F.A.R.C.S., L. FAHY, M.B., B.CH., F.F.A.R.C.S., F.F.A.R.C.S.I. and P. CHARTERS, M.D., M.R.C.P., F.F.A.R.C.S. B.A.

Arrowe Park Hospital Arrowe Park Road, Upton, Wirral L49 5PE
Royal Liverpool Hospital Prescot Street, P.O. Box 147, Liverpool L69 3BX

Correspondence to P.C.

Study of patients who exhibit only limited morphological abnormality yet present difficulty with direct laryngoscopy is facilitated by a standard intubating position. The "Angle Finder" instrument allows implementation of a simple reproducible geometric standard which is applied easily in formal research work and in clinical practice and teaching. The proposed standard relates to the curved (Macintosh) laryngoscope blade and a supine patient. The lower neck flexion is 35° and extension of the plane of the face 15°, each angle measured relative to horizontal. Initially, the standard was derived from a review of the literature, then validated in a study of the intubating practices of 10 senior anaesthetists. A more detailed study of 10 normal volunteers confirmed reproducibility and, for nine patients with a history of difficult direct laryngoscopy, the standard was shown to be appropriate.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
S. D. Aiken, N. Delson, T. M. Davidson, and R. H. Hastings
A Two-Dimensional Model of Anatomic Relationships During Laryngoscopy
Anesth. Analg., October 1, 2007; 105(4): 1118 - 1126.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. D. Mentzelopoulos, M. Tzoufi, K. Rellos, A. S. Michalopoulos, E. Stamataki, C. Roussos, and S. G. Zakynthinos
An Evaluation of McCoy Balloon Laryngoscopy in Patients With Moderate-to-Major Endotracheal Intubation Difficulty
Anesth. Analg., October 1, 2005; 101(4): 1233 - 1237.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. D. Mentzelopoulos, C. N. Romana, D. S. Corolanoglou, M. J. Tzoufi, and E. A. Karamichali
Balloon Versus Conventional Laryngoscopy: A Comparison of Laryngoscopic Findings and Intubation Difficulty
Anesth. Analg., December 1, 2000; 91(6): 1513 - 1519.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.