Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by GOODMAN, N. W.
Right arrow Articles by CURNOW, J. S. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by GOODMAN, N. W.
Right arrow Articles by CURNOW, J. S. H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

British Journal of Anaesthesia, 1985, Vol. 57, No. 3 311-318
© 1985 The Board of Management and Trustees of the British Journal of Anaesthesia


research-article

THE VENTILATORY RESPONSE TO CARBON DIOXIDE

An Analysis of Data Obtained by the Rebreathing Method

N. W. GOODMAN, M.A., D.PHIL., B.M., B.CH., F.F.A.R.C.S. and J. S. H. CURNOW, B.SC., C.ENG., M.I.E.E.*

Department of Anaesthesia, Bristol Royal Infirmary Bristol BS2 8HW

The ventilatory response to carbon dioxide using the rebreathing method was studied repeatedly in four healthy volunteers. The data were collected and processed in different ways using a microcomputer. Least squares linear regression analysis described the responses almost as accurately as a non-linear second-order polynomial regression. Linear regression analysis was undertaken on Vi/PE'CO2 points, first breath-by-breath and then on three different groupings of breaths. The gradients and intercepts obtained by grouping agreed with those from breath-by-breath-analysis both for a single response and for the mean result of a number of responses. Grouping tended to increase the correlation coefficient of a response, but widened the statistical confidence limits of the calculated gradient. The performance variability between repeated responses, the same no matter which data points were used, produced a range of gradients for each subject which was larger than the confidence limits on the gradient of a single response.

* Present address: Department of Medical Physics and Biomedical Engineering, Plymouth General Hospital, Freedom Fields, Plymouth.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.